6 #define VERSION "3.1.7"
7 #define BDATE "10 December 2009"
8 #define LSMDATE "10Dec09"
10 #define PROG_COPYRIGHT "Copyright (C) %d-2009 Free Software Foundation Europe e.V.\n"
11 #define BYEAR "2009" /* year for copyright messages in progs */
14 Bacula® - The Network Backup Solution
16 Copyright (C) 2000-2009 Free Software Foundation Europe e.V.
18 The main author of Bacula is Kern Sibbald, with contributions from
19 many others, a complete list can be found in the file AUTHORS.
20 This program is Free Software; you can redistribute it and/or
21 modify it under the terms of version two of the GNU General Public
22 License as published by the Free Software Foundation and included
25 This program is distributed in the hope that it will be useful, but
26 WITHOUT ANY WARRANTY; without even the implied warranty of
27 MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
28 General Public License for more details.
30 You should have received a copy of the GNU General Public License
31 along with this program; if not, write to the Free Software
32 Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
35 Bacula® is a registered trademark of Kern Sibbald.
36 The licensor of Bacula is the Free Software Foundation Europe
37 (FSFE), Fiduciary Program, Sumatrastrasse 25, 8006 Zürich,
38 Switzerland, email:ftf@fsfeurope.org.
48 /* If this is set stdout will not be closed on startup */
52 * SMCHECK does orphaned buffer checking (memory leaks)
53 * it can always be turned on, but has some minor performance
61 * _USE_LOCKMGR does lock/unlock mutex tracking (dead lock)
62 * it can always be turned on, but we advise to use it only
70 * Enable priority management with the lock manager
72 * Note, turning this on will cause the Bacula SD to abort if
73 * mutexes are executed out of order, which could lead to a
74 * deadlock. However, note that this is not necessarily a
75 * deadlock, so turn this on only for debugging.
77 //# define USE_LOCKMGR_PRIORITY
85 * USE_VTAPE is a dummy tape driver. This is useful to
93 * for fastest speed but you must have a UPS to avoid unwanted shutdowns
95 //#define SQLITE3_INIT_QUERY "PRAGMA synchronous = OFF"
98 * for more safety, but is 30 times slower than above
100 #define SQLITE3_INIT_QUERY "PRAGMA synchronous = NORMAL"
103 * This should always be on. It enables data encryption code
104 * providing it is configured.
106 #define DATA_ENCRYPTION 1
109 * This uses a Bacula specific bsnprintf rather than the sys lib
110 * version because it is much more secure. It should always be
113 #define USE_BSNPRINTF 1
115 /* Debug flags not normally turned on */
117 /* #define TRACE_JCR_CHAIN 1 */
118 /* #define TRACE_RES 1 */
119 /* #define DEBUG_MEMSET 1 */
120 /* #define DEBUG_MUTEX 1 */
123 * Set SMALLOC_SANITY_CHECK to zero to turn off, otherwise
124 * it is the maximum memory malloced before Bacula will
125 * abort. Except for debug situations, this should be zero
127 #define SMALLOC_SANITY_CHECK 0 /* 500000000 0.5 GB max */
130 /* Check if header of tape block is zero before writing */
131 /* #define DEBUG_BLOCK_ZEROING 1 */
133 /* #define FULL_DEBUG 1 */ /* normally on for testing only */
135 /* Turn this on ONLY if you want all Dmsg() to append to the
136 * trace file. Implemented mainly for Win32 ...
138 /* #define SEND_DMSG_TO_FILE 1 */
141 /* The following are turned on for performance testing */
143 * If you turn on the NO_ATTRIBUTES_TEST and rebuild, the SD
144 * will receive the attributes from the FD, will write them
145 * to disk, then when the data is written to tape, it will
146 * read back the attributes, but they will not be sent to
147 * the Director. So this will eliminate: 1. the comm time
148 * to send the attributes to the Director. 2. the time it
149 * takes the Director to put them in the catalog database.
151 /* #define NO_ATTRIBUTES_TEST 1 */
154 * If you turn on NO_TAPE_WRITE_TEST and rebuild, the SD
155 * will do all normal actions, but will not write to the
156 * Volume. Note, this means a lot of functions such as
157 * labeling will not work, so you must use it only when
158 * Bacula is going to append to a Volume. This will eliminate
159 * the time it takes to write to the Volume (not the time
160 * it takes to do any positioning).
162 /* #define NO_TAPE_WRITE_TEST 1 */
165 * If you turn on FD_NO_SEND_TEST and rebuild, the FD will
166 * not send any attributes or data to the SD. This will
167 * eliminate the comm time sending to the SD.
169 /* #define FD_NO_SEND_TEST 1 */