#!/bin/sh # # Run a simple backup of the Bacula build directory but # split the archive into four volumes, two of which are # totally full. I.e. make sure that bsr selects all tapes # including those fully spanned. # TestName="span-vol-test" JobName=SpanVol . scripts/functions set_debug 0 cwd=`pwd` scripts/copy-test-confs scripts/cleanup echo "${cwd}/build" >/tmp/file-list change_jobname NightlySave $JobName start_test cat <tmp/bconcmds @output /dev/null messages @$out tmp/log1.out label storage=File1 volume=TestVolume004 label storage=File1 volume=TestVolume003 label storage=File1 volume=TestVolume002 label storage=File1 volume=TestVolume001 update Volume=TestVolume004 MaxVolBytes=3000000 update Volume=TestVolume003 MaxVolBytes=3000000 update Volume=TestVolume002 MaxVolBytes=3000000 run job=$JobName storage=File1 yes wait list volumes messages @# @# now do a restore @# @$out tmp/log2.out restore where=${cwd}/tmp/bacula-restores select storage=File1 unmark * mark * done yes wait messages @$out quit END_OF_DATA run_bacula check_for_zombie_jobs storage=File1 stop_bacula check_two_logs check_restore_diff end_test