#!/bin/sh # # Run backups with dummy tape driver # This test setups an Autochanger with 80 slots # and 5 drives (3 LTO3 and 2 LTO1) # # TAPE_DRIVE="$cwd/working/ach/drive0" # TAPE_DRIVE1="$cwd/working/ach/drive0" # AUTOCHANGER="$cwd/working/ach/conf" # USE_VTAPE=yes # AUTOCHANGER_SCRIPT=disk-changer # TestName="vtape-test-changer" JobName=backup . scripts/functions require_vtape scripts/cleanup scripts/copy-tape-confs cp $rscripts/bacula-dir-vtape.conf $conf/bacula-dir.conf cp $rscripts/bacula-sd-vtape.conf $conf/bacula-sd.conf scripts/prepare-fake-autochanger echo "${cwd}/build" >${cwd}/tmp/file-list start_test when1=`perl -MPOSIX -e "print strftime('%F %T', localtime(time+30))"` when2=`perl -MPOSIX -e "print strftime('%F %T', localtime(time+45))"` clientname=`awk '/Name = .*-fd/ { if (!ok) { print $3 ; ok=1 } }' bin/bacula-dir.conf` # Catalog record for cleaning tape "CLN01" successfully created. # CLN01 | Cleaning # Write out bconsole commands cat <${cwd}/tmp/bconcmds @$out /dev/null messages @$out ${cwd}/tmp/log6.out @#setdebug level=200 storage=LTO1 label barcodes pool=Scratch slots=1-14 storage=LTO1-ANSI_6 drive=6 yes label barcodes pool=Scratch slots=15-40 storage=LTO1 drive=3 yes messages list volumes END_OF_DATA run_bacula cat <${cwd}/tmp/bconcmds @$out ${cwd}/tmp/log7.out label barcodes pool=Scratch slots=41-80 storage=LTO3 drive=0 yes messages list volumes @$out ${cwd}/tmp/log1.out run storage=LTO3 when="$when1" job=NightlySave pool=Inc yes run storage=LTO3 when="$when1" job=NightlySave2 pool=Full yes run storage=LTO3 when="$when1" job=NightlySave1 pool=Default yes run storage=LTO1 when="$when1" job=NightlySave pool=Inc yes run storage=LTO1 when="$when1" job=NightlySave2 pool=Full yes run storage=LTO1 when="$when1" job=NightlySave1 pool=Default yes run storage=LTO1 when="$when1" job=NightlySave3 pool=Diff yes run storage=LTO1-ANSI_6 when="$when2" job=NightlySave pool=Inc yes wait messages quit END_OF_DATA run_bconsole check_for_zombie_jobs storage=LTO1 client=$clientname check_for_zombie_jobs storage=LTO3 client=$clientname check_for_zombie_jobs storage=LTO1-ANSI_6 client=$clientname touch ${cwd}/build/po/*.po cat <${cwd}/tmp/bconcmds @$out ${cwd}/tmp/log2.out run storage=LTO1-ANSI_6 job=NightlySave3 pool=Inc yes wait messages @# @# now do a restore @# restore client=$clientname fileset="Full Set" pool=Diff where=${cwd}/tmp/bacula-restores select all done yes wait messages wait messages END_OF_DATA run_bconsole check_for_zombie_jobs storage=LTO1 client=$clientname check_for_zombie_jobs storage=LTO3 client=$clientname check_for_zombie_jobs storage=LTO1-ANSI_6 client=$clientname # test update slots # remove volume vol35 from autochanger grep -v vol35 ${cwd}/working/ach/barcodes > ${cwd}/tmp/1 cp ${cwd}/tmp/1 ${cwd}/working/ach/barcodes cat <${cwd}/tmp/bconcmds @$out ${cwd}/tmp/log3.out list volume=vol35 update slots slots=15-40 storage=LTO1 drive=3 list volume=vol35 END_OF_DATA run_bconsole stop_bacula check_two_logs check_restore_diff # get InChanger flag RES=`awk -F'|' '/vol35.+Append/ { print $11 }' ${cwd}/tmp/log3.out` set $RES if [ $1 -eq $2 ]; then print_debug "ERROR: Error in update slots" bstat=1 fi grep LTO1_5 tmp/log1.out > /dev/null if test $? = 0; then print_debug "ERROR: AutoSelect option broken" bstat=1 fi grep 'Error: Re-read' tmp/log1.out > /dev/null if test $? = 0; then print_debug "ERROR: Found Re-read errors" bstat=1 fi end_test