+Common fan control attributes
+-----------------------------
+
+pwm[1-5]_temp_sel Temperature source. Value is temperature sensor index.
+ For example, select '1' for temp1_input.
+pwm[1-5]_weight_temp_sel
+ Secondary temperature source. Value is temperature
+ sensor index. For example, select '1' for temp1_input.
+pwm[1-5]_weight_enable Set to 1 to enable secondary temperature control.
+
+If secondary temperature functionality is enabled, it is controlled with the
+following attributes.
+
+pwm[1-5]_weight_duty_step
+ Duty step size.
+pwm[1-5]_weight_temp_step
+ Temperature step size. With each step over
+ temp_step_base, the value of weight_duty_step is added
+ to the current pwm value.
+pwm[1-5]_weight_temp_step_base
+ Temperature at which secondary temperature control kicks
+ in.
+pwm[1-5]_weight_temp_step_tol
+ Temperature step tolerance or hysteresis. This is a
+ relative value.
+
+
+Thermal Cruise mode (2)
+-----------------------