# volumes to be recycled, and cycling through the volumes
# twice. Tests maxvoljobs and volretention.
#
+# Note, this test is a bit tricky, in that if you get too
+# much data in the regress/build directory, the test will
+# fail because it will run out of enough volumes to backup
+# all the data.
+#
TestName="recycle-test"
JobName=Recycle
. scripts/functions
start_test
cat <<END_OF_DATA >${cwd}/tmp/bconcmds
-@output /dev/null
+@$out /dev/null
messages
@$out ${cwd}/tmp/log1.out
label storage=File1 volume=TestVolume001
label storage=File1 volume=TestVolume002
label storage=File1 volume=TestVolume003
-update Volume=TestVolume001 volretention=10s
+label storage=File1 volume=TestVolume004
+@# Note, this is going to fail if the pruning gets
+@# to tight because the saved volume is too large.
+@# In that case, either add another volume, or
+@# increase the volume capacity a bit.
+update Volume=TestVolume001 volretention=5s
update Volume=TestVolume001 maxvolbytes=200000000
-update Volume=TestVolume002 volretention=10s
+update Volume=TestVolume002 volretention=5s
update Volume=TestVolume002 maxvolbytes=200000000
-update Volume=TestVolume003 volretention=10s
+update Volume=TestVolume003 volretention=5s
update Volume=TestVolume003 maxvolbytes=200000000
+update Volume=TestVolume004 volretention=5s
+update Volume=TestVolume004 maxvolbytes=200000000
list volumes
-@#setdebug level=100 storage=File1
+setdebug level=150 storage=File1
+setdebug level=50 dir
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
wait
messages
list volumes
-@sleep 11
+@sleep 12
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
wait
messages
list volumes
-@sleep 11
+@sleep 12
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
wait
messages
list volumes
-@sleep 11
+@sleep 12
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
wait
messages
list volumes
-@sleep 11
+@sleep 12
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
run job=$JobName storage=File1 level=full yes
yes
wait
messages
-@output
quit
END_OF_DATA