stlink: add SWO tracing support
Enable reading the SWO trace output via STLinkv2 dongles that support
it.
This adds an optional initialization parameter "trace" with which the user
specifies a destination file where SWO trace output is appended as it comes in
as well as the trace module's source clock rate.
STLink will be configured for a 2MHz SWO data rate (STLink's highest
supported rate) if the source clock is > 2MHz, otherwise the source
clock is used as the data rate directly.
For example:
trace swo.log
168000000
If "trace" is specified with a usable file path, the stlink_usb driver will
attempt to configure and read SWO trace data as follows:
- on _run(), the target's TPI and TMI are configured and the STLinkv2 is told
to enable tracing. Only generic ARM TPI and TMI registers are
configured, any MCU-specific settings (ex: pin routing) are the
responsibility of the target firmware. The configuration applied is
based on the STLinkv2's capabilities (UART emulation).
- on _v2_get_status(), the trace data (if any) is fetched from the
STLink after the target status is checked and the target is found to
be running.
- on _halt(), the STLink is told to disable tracing.
When fetching trace data, the entire trace frame is written to the output file
and that data is flushed. An external tool may be used to parse the
trace data into a more human-readable format.
Tested on ARM Cortex M4F and M3 MCUs (STM32F407 and STM32L152).
Change-Id: Ic3983d46c82ba77010c23b0e18ce7b275d917f12
Signed-off-by: Andrey Yurovsky <yurovsky@gmail.com>
Reviewed-on: http://openocd.zylin.com/1524
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
Reviewed-by: Andreas Fritiofson <andreas.fritiofson@gmail.com>