fi
echo "Starting slapd on TCP/IP port $PORT1..."
-mkdir testrun/confdir
-$SLAPD -f $CONF1 -F testrun/confdir -h $URI1 -d $LVL $TIMING > $LOG1 2>&1 &
+mkdir $TESTDIR/confdir
+$SLAPD -f $CONF1 -F $TESTDIR/confdir -h $URI1 -d $LVL $TIMING > $LOG1 2>&1 &
PID=$!
if test $WAIT != 0 ; then
echo PID $PID
fi
echo Dynamically retrieving initial configuration...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/initial-config.ldif
-cat <<EOF >testrun/initial-reference.ldif
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/initial-config.ldif
+cat <<EOF >$TESTDIR/initial-reference.ldif
dn: olcOverlay={0}unique,olcDatabase={1}$BACKEND,cn=config
objectClass: olcOverlayConfig
objectClass: olcUniqueConfig
olcUniqueAttribute: displayName
EOF
-diff testrun/initial-config.ldif testrun/initial-reference.ldif > /dev/null 2>&1
+diff $TESTDIR/initial-config.ldif $TESTDIR/initial-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Initial configuration is not reported correctly."
fi
echo Verifying initial configuration intact...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/initial-config-recheck.ldif
-diff testrun/initial-config-recheck.ldif testrun/initial-reference.ldif > /dev/null 2>&1
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/initial-config-recheck.ldif
+diff $TESTDIR/initial-config-recheck.ldif $TESTDIR/initial-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Initial configuration damaged by unsuccessful modifies."
fi
echo Verifying base removal...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/baseremoval-config.ldif
-cat >testrun/baseremoval-reference.ldif <<EOF
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/baseremoval-config.ldif
+cat >$TESTDIR/baseremoval-reference.ldif <<EOF
dn: olcOverlay={0}unique,olcDatabase={1}$BACKEND,cn=config
objectClass: olcOverlayConfig
objectClass: olcUniqueConfig
olcUniqueAttribute: displayName
EOF
-diff testrun/baseremoval-config.ldif testrun/baseremoval-reference.ldif > /dev/null 2>&1
+diff $TESTDIR/baseremoval-config.ldif $TESTDIR/baseremoval-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Configuration damaged by base removal"
fi
echo Dynamically retrieving second configuration...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/second-config.ldif
-cat >testrun/second-reference.ldif <<EOF
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/second-config.ldif
+cat >$TESTDIR/second-reference.ldif <<EOF
dn: olcOverlay={0}unique,olcDatabase={1}$BACKEND,cn=config
objectClass: olcOverlayConfig
objectClass: olcUniqueConfig
olcUniqueURI: ldap:///?description?one
EOF
-diff testrun/second-config.ldif testrun/second-reference.ldif > /dev/null 2>&1
+diff $TESTDIR/second-config.ldif $TESTDIR/second-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Second configuration is not reported correctly."
fi
echo Verifying second configuration intact...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/second-config-recheck.ldif
-diff testrun/second-config-recheck.ldif testrun/second-reference.ldif > /dev/null 2>&1
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/second-config-recheck.ldif
+diff $TESTDIR/second-config-recheck.ldif $TESTDIR/second-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Second configuration damaged by rejected modifies."
fi
echo Dynamically retrieving third configuration...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/third-config.ldif
-cat >testrun/third-reference.ldif <<EOF
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/third-config.ldif
+cat >$TESTDIR/third-reference.ldif <<EOF
dn: olcOverlay={0}unique,olcDatabase={1}$BACKEND,cn=config
objectClass: olcOverlayConfig
objectClass: olcUniqueConfig
olcUniqueURI: ldap:///?sn?sub?(cn=e*)
EOF
-diff testrun/third-config.ldif testrun/third-reference.ldif > /dev/null 2>&1
+diff $TESTDIR/third-config.ldif $TESTDIR/third-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Third configuration is not reported correctly."
fi
echo Dynamically retrieving fourth configuration...
-$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >testrun/fourth-config.ldif
-cat >testrun/fourth-reference.ldif <<EOF
+$LDAPSEARCH -S "" -b olcOverlay='{0}'unique,olcDatabase='{1}'$BACKEND,cn=config -D cn=config -y $CONFIGPWF -h $LOCALHOST -p $PORT1 -LLL | tr -d \\r >$TESTDIR/fourth-config.ldif
+cat >$TESTDIR/fourth-reference.ldif <<EOF
dn: olcOverlay={0}unique,olcDatabase={1}$BACKEND,cn=config
objectClass: olcOverlayConfig
objectClass: olcUniqueConfig
olcUniqueURI: ignore ldap:///?objectClass,uid,cn,sn?sub
EOF
-diff testrun/fourth-config.ldif testrun/fourth-reference.ldif > /dev/null 2>&1
+diff $TESTDIR/fourth-config.ldif $TESTDIR/fourth-reference.ldif > /dev/null 2>&1
RC=$?
if test $RC != 0 ; then
echo "Fourth configuration is not reported correctly."