* POWER_SUPPLY_CHARGE_NOW is the unit of measurement. The energy is
* given in mWh, the charge in mAh. So calculate every value given in
* ampere to watt */
- if (!watt_as_unit && voltage != -1) {
- batt_info->present_rate = (((float)voltage / 1000.0) * ((float)batt_info->present_rate / 1000.0));
- batt_info->remaining = (((float)voltage / 1000.0) * ((float)batt_info->remaining / 1000.0));
- batt_info->full_design = (((float)voltage / 1000.0) * ((float)batt_info->full_design / 1000.0));
- batt_info->full_last = (((float)voltage / 1000.0) * ((float)batt_info->full_last / 1000.0));
+ if (!watt_as_unit && voltage >= 0) {
+ if (batt_info->present_rate > 0) {
+ batt_info->present_rate = (((float)voltage / 1000.0) * ((float)batt_info->present_rate / 1000.0));
+ }
+ if (batt_info->remaining > 0) {
+ batt_info->remaining = (((float)voltage / 1000.0) * ((float)batt_info->remaining / 1000.0));
+ }
+ if (batt_info->full_design > 0) {
+ batt_info->full_design = (((float)voltage / 1000.0) * ((float)batt_info->full_design / 1000.0));
+ }
+ if (batt_info->full_last > 0) {
+ batt_info->full_last = (((float)voltage / 1000.0) * ((float)batt_info->full_last / 1000.0));
+ }
}
#elif defined(__FreeBSD__) || defined(__FreeBSD_kernel__) || defined(__DragonFly__)
int state;
return;
}
- int full = (last_full_capacity ? batt_info.full_last : batt_info.full_design);
- if (full < 0 && batt_info.percentage_remaining < 0) {
+ // *Choose* a measure of the 'full' battery. It is whichever is better of
+ // the battery's (hardware-given) design capacity (batt_info.full_design)
+ // and the battery's last known good charge (batt_info.full_last).
+ // We prefer the design capacity, but use the last capacity if we don't have it,
+ // or if we are asked to (last_full_capacity == true); but similarly we use
+ // the design capacity if we don't have the last capacity.
+ // If we don't have either then both full_design and full_last < 0,
+ // which implies full < 0, which bails out on the following line.
+ int full = batt_info.full_design;
+ if (full < 0 || (last_full_capacity && batt_info.full_last >= 0)) {
+ full = batt_info.full_last;
+ }
+ if (full < 0 && batt_info.remaining < 0 && batt_info.percentage_remaining < 0) {
/* We have no physical measurements and no estimates. Nothing
* much we can report, then. */
OUTPUT_FULL_TEXT(format_down);