From: Jasper Lievisse Adriaanse Date: Wed, 10 Oct 2012 07:53:34 +0000 (+0200) Subject: i3status - Default to acpitz(4) instead of cpu(4) for OpenBSD temperature readings X-Git-Tag: 2.7~30 X-Git-Url: https://git.sur5r.net/?a=commitdiff_plain;h=1c2517a3998385dbfca0559aca3ba7e72b5c216c;p=i3%2Fi3status i3status - Default to acpitz(4) instead of cpu(4) for OpenBSD temperature readings The acpitz(4) values are eventually used by the kernel to determine if the machine is getting too hot. --- diff --git a/include/i3status.h b/include/i3status.h index 2317936..93f9791 100644 --- a/include/i3status.h +++ b/include/i3status.h @@ -31,9 +31,11 @@ enum { O_DZEN2, O_XMOBAR, O_I3BAR, O_NONE } output_format; * Due to the fact there are various ways to obtain a temperature reading, THERMAL_ZONE will need * to be adjustable enough for those situations. As it can either be hw.sensors.cpu%d.temp0, or * hw.sensors.acpitz%d.temp0 or even something different entirely within hw.sensors.%s.temp0. - * XXX: For now just check cpu%d.temp0. Adjust this later. + * XXX: + * Due to the fact the i3status API only allows to set the THERMAL_ZONE parameter to an integer, + * we can't make this fully configureable (yet?). */ -#define THERMAL_ZONE "cpu%d" +#define THERMAL_ZONE "acpitz%d" #endif diff --git a/src/print_cpu_temperature.c b/src/print_cpu_temperature.c index 8e7d7f9..b1d1221 100644 --- a/src/print_cpu_temperature.c +++ b/src/print_cpu_temperature.c @@ -88,18 +88,19 @@ void print_cpu_temperature_info(yajl_gen json_gen, char *buffer, int zone, const goto error; } /* - * 'path' is actually the node within the full path (eg, cpu0). + * 'path' is actually the node within the full path (currently always acpitz0). * XXX: Extend the API to allow a string instead of just an int for path, this would - * allow us to have a path of 'acpitz0' for example. + * allow us to build an arbitrary path. */ if (strncmp(sensordev.xname, path, strlen(path)) == 0) { mib[3] = SENSOR_TEMP; for (numt = 0; numt < sensordev.maxnumt[SENSOR_TEMP]; numt++) { mib[4] = numt; if (sysctl(mib, 5, &sensor, &slen, NULL, 0) == -1) { - if (errno != ENOENT) + if (errno != ENOENT) { warn("sysctl"); - continue; + continue; + } } outwalk += sprintf(outwalk, "%.2f", (sensor.value - 273150000) / 1000000.0 ); }