From: Kern Sibbald Date: Sat, 5 Mar 2011 12:44:03 +0000 (+0100) Subject: Attempt to disactivate old exchange-fd.dll if no plugin= line in FileSet X-Git-Url: https://git.sur5r.net/?a=commitdiff_plain;h=9611070c1c611482be1135f81bb983293c5e4289;p=bacula%2Fbacula Attempt to disactivate old exchange-fd.dll if no plugin= line in FileSet --- diff --git a/bacula/src/win32/filed/plugins/exchange-fd.c b/bacula/src/win32/filed/plugins/exchange-fd.c index d82a93cb8f..d0dc0bf422 100644 --- a/bacula/src/win32/filed/plugins/exchange-fd.c +++ b/bacula/src/win32/filed/plugins/exchange-fd.c @@ -1,7 +1,7 @@ /* Bacula® - The Network Backup Solution - Copyright (C) 2008-2010 Free Software Foundation Europe e.V. + Copyright (C) 2010-2011 Bacula Systems(R) SA The main author of Bacula is Kern Sibbald, with contributions from many others, a complete list can be found in the file AUTHORS. @@ -126,8 +126,7 @@ loadPlugin(bInfo *lbinfo, bFuncs *lbfuncs, pInfo **pinfo, pFuncs **pfuncs) *pinfo = &pluginInfo; *pfuncs = &pluginFuncs; retval = loadExchangeApi(); - if (retval != bRC_OK) - { + if (retval != bRC_OK) { printf("Cannot load Exchange DLL\n"); return retval; } @@ -167,6 +166,7 @@ static bRC newPlugin(bpContext *ctx) context->bpContext = ctx; context->job_since = 0; context->notrunconfull_option = false; + context->plugin_active = false; bfuncs->getBaculaValue(ctx, bVarJobId, (void *)&JobId); _DebugMessage(0, "newPlugin JobId=%d\n", JobId); bfuncs->registerBaculaEvents(ctx, 1, 2, 0); @@ -211,23 +211,40 @@ static bRC handlePluginEvent(bpContext *ctx, bEvent *event, void *value) char *name; int i, intval; int accurate; + char *command; + char *plugin_name; switch (event->eventType) { case bEventJobStart: _DebugMessage(0, "JobStart=%s\n", (char *)value); + context->plugin_active = false; break; case bEventJobEnd: _DebugMessage(0, "JobEnd\n"); break; + case bEventPluginCommand: + _DebugMessage(0, "bEventPluginCommand %s\n", value); + command = bstrdup((char *)value); + /* this isn't really unused */ + plugin_name = strtok((char *)command, ":"); + if (strcmp(plugin_name, "exchange") != 0) { + context->plugin_active = false; + } else { + context->plugin_active = true; + } + free(command); + break; case bEventStartBackupJob: + if (!context->plugin_active) { + break; + } _DebugMessage(0, "BackupStart\n"); bfuncs->getBaculaValue(ctx, bVarAccurate, (void *)&accurate); context->accurate = accurate; context->job_type = JOB_TYPE_BACKUP; // level should have been specified by now - check it // if level is D or I, since should have been specified too - switch (context->job_level) - { + switch (context->job_level) { case 'F': if (context->notrunconfull_option) { context->truncate_logs = false; @@ -248,13 +265,22 @@ static bRC handlePluginEvent(bpContext *ctx, bEvent *event, void *value) break; case bEventEndBackupJob: _DebugMessage(0, "BackupEnd\n"); + if (!context->plugin_active) { + break; + } break; case bEventLevel: + if (!context->plugin_active) { + break; + } intval = (intptr_t)value; _DebugMessage(0, "JobLevel=%c %d\n", intval, intval); context->job_level = intval; break; case bEventSince: + if (!context->plugin_active) { + break; + } intval = (intptr_t)value; _DebugMessage(0, "since=%d\n", intval); context->job_since = (time_t)value; @@ -262,17 +288,28 @@ static bRC handlePluginEvent(bpContext *ctx, bEvent *event, void *value) case bEventStartRestoreJob: _DebugMessage(0, "StartRestoreJob\n"); context->job_type = JOB_TYPE_RESTORE; + context->plugin_active = true; break; case bEventEndRestoreJob: + if (!context->plugin_active) { + break; + } _DebugMessage(0, "EndRestoreJob\n"); + context->plugin_active = false; break; /* Plugin command e.g. plugin = ::command */ case bEventRestoreCommand: _DebugMessage(0, "restore\n"); // command=%s\n", (char *)value); + if (!context->plugin_active) { + break; + } break; case bEventBackupCommand: + if (!context->plugin_active) { + break; + } { _DebugMessage(0, "backup command=%s\n", (char *)value); char *command = new char[strlen((char *)value)]; @@ -280,39 +317,33 @@ static bRC handlePluginEvent(bpContext *ctx, bEvent *event, void *value) char *plugin_name = strtok((char *)command, ":"); char *path = strtok(NULL, ":"); char *option; - while ((option = strtok(NULL, ":")) != NULL) - { + while ((option = strtok(NULL, ":")) != NULL) { _DebugMessage(100, "option %s\n", option); - if (stricmp(option, "notrunconfull") == 0) - { + if (stricmp(option, "notrunconfull") == 0) { context->notrunconfull_option = true; - } - else - { + } else { _JobMessage(M_WARNING, "Unknown plugin option '%s'\n", option); } } _DebugMessage(0, "name = %s\n", plugin_name); _DebugMessage(0, "path = %s\n", path); - if (*path != '/') - { + if (*path != '/') { _JobMessage(M_FATAL, "Path does not begin with a '/'\n"); return bRC_Error; } - for (i = 0; i < 6; i++) + for (i = 0; i < 6; i++) { context->path_bits[i] = NULL; + } char *path_bit = strtok(path, "/"); - for (i = 0; path_bit != NULL && i < 6; i++) - { + for (i = 0; path_bit != NULL && i < 6; i++) { context->path_bits[i] = new char[strlen(path_bit) + 1]; strcpy(context->path_bits[i], path_bit); path_bit = strtok(NULL, "/"); } - if (i < 2 || i > 4) - { + if (i < 2 || i > 4) { _JobMessage(M_FATAL, "Invalid plugin backup path\n"); return bRC_Error; } @@ -337,8 +368,7 @@ startBackupFile(bpContext *ctx, struct save_pkt *sp) node_t *current_node; _DebugMessage(100, "startBackupFile, cmd = %s\n", sp->cmd); - if (sp->pkt_size != sizeof(struct save_pkt) || sp->pkt_end != sizeof(struct save_pkt)) - { + if (sp->pkt_size != sizeof(struct save_pkt) || sp->pkt_end != sizeof(struct save_pkt)) { _JobMessage(M_FATAL, "save_pkt size mismatch - sizeof(struct save_pkt) = %d, pkt_size = %d, pkt_end = %d\n", sizeof(struct save_pkt), sp->pkt_size, sp->pkt_end); return bRC_Error; } diff --git a/bacula/src/win32/filed/plugins/exchange-fd.h b/bacula/src/win32/filed/plugins/exchange-fd.h index 1237a988b8..67dcf6128d 100644 --- a/bacula/src/win32/filed/plugins/exchange-fd.h +++ b/bacula/src/win32/filed/plugins/exchange-fd.h @@ -1,7 +1,7 @@ /* Bacula® - The Network Backup Solution - Copyright (C) 2008-2008 Free Software Foundation Europe e.V. + Copyright (C) 2010-2011 Bacula Systems(R) SA The main author of Bacula is Kern Sibbald, with contributions from many others, a complete list can be found in the file AUTHORS. @@ -134,6 +134,7 @@ struct exchange_fd_context_t { bool notrunconfull_option; bool truncate_logs; bool accurate; + bool plugin_active; }; static inline char *tocharstring(WCHAR *src)