From a47f2727ff242d62b7c5e67fe6e8afa290c63950 Mon Sep 17 00:00:00 2001 From: cuz Date: Sat, 8 Jul 2000 21:10:42 +0000 Subject: [PATCH] Update for new features/version git-svn-id: svn://svn.cc65.org/cc65/trunk@138 b7a2c559-68d2-44c3-8de9-860c34a00d81 --- doc/ca65.txt | 331 +++++++++++++++++++++++++++++++++++++-------------- 1 file changed, 243 insertions(+), 88 deletions(-) diff --git a/doc/ca65.txt b/doc/ca65.txt index d46a93844..7aeda7c48 100644 --- a/doc/ca65.txt +++ b/doc/ca65.txt @@ -4,7 +4,7 @@ A Macro Crossassembler for the 6502/65C02/65816 CPUs - (C) Copyright 1998-1999 Ullrich von Bassewitz + (C) Copyright 1998-2000 Ullrich von Bassewitz (uz@musoftware.de) @@ -95,12 +95,6 @@ development: this decision, but I've written several multipass assemblers, and it started to get boring. A one pass assembler needs much more elaborated data structures, and because of that it's much more fun:-) - There is one drawback with this point: It is nearly impossible to - generate a listing when reading the source file only once without - storing the source file in memory. Consequently, the assembler is not - able to produce a listing. This could be added by reading the source - file a second time if a listing was requested, but I didn't see an - urgent need for a listing, so this was not a disadvantage for me. * Non-GPLed code that may be used in any project without restrictions or fear of "GPL infecting" other code. @@ -112,81 +106,162 @@ development: The assembler accepts the following options: - -g Generate debug info - -i Ignore case of symbols - -l Create a listing if assembly was ok - -o name Name the output file - -s Enable smart mode - -v Increase verbosity - -D name[=value] Define a symbol - -U Mark unresolved symbols as import - -V Print the assembler version - -W n Set warning level n - --cpu type Set cpu type - --pagelength n Set the page length for the listing - --smart Enable smart mode - -When the -g option (or the equivalent control command .DEBUGINFO) is used, -the assembler will add a section to the object file that contains all -symbols (including local ones) together with the symbol values and source -file positions. The linker will put these additional symbols into the -VICE label file, so even local symbols can be seen in the VICE monitor. - -The option -i makes the assembler case insensitive on identifiers and -labels. This option will override the default, but may itself be overriden -by the .CASE control command (see section 6). - -The default output name is the name of the input file with the extension -replaced by ".o". If you don't like that, you may give another name with -the -o option. The output file will be placed in the same directory as the -source file, or, if -o is given, the full path in this name is used. - -In smart mode (enabled by -s or the .SMART pseudo instruction) the -assembler will track usage of the REP and SEP instructions in 65816 mode -and update the operand sizes accordingly. If the operand of such an -instruction cannot be evaluated by the assembler (for example, because the -operand is an imported symbol), a warning is issued. Beware: Since the -assembler cannot trace the execution flow this may lead to false results -in some cases. If in doubt, use the .ixx and .axx instructions to tell the -assembler about the current settings. Smart mode is off by default. - --v does increase the assembler verbosity and is usually only needed for -debugging purposes. You may use this option more than one time for even -more verbose output. - --D allows you to predefine symbols on the command line. Without a value, -the symbol is defined with the value zero. When giving a value, you may -use the '$' prefix for hexadecimal symbols. Please note that for some -operating systems, '$' has a special meaning, so you may have to quote -the expression. - --U marks symbols that are not defined in the sources as imported symbols. -This should be used with care since it delays error messages about typos -and such until the linker is run. The compiler uses the equivalent of -this switch (.AUTOIMPORT, see control command section below) to enable -auto imported symbols for the runtime library. However, the compiler is -supposed to generate code that runs through the assembler without -problems, something which is not always true for assembler programmers. - --V prints the version number of the assembler. If you send any suggestions -or bugfixes, please include your version number. - --Wn sets the warning level for the assembler. Using -W2 the assembler will -even warn about such things like unused imported symbols. The default -warning level is 1, and it would probably be silly to set it to something -lower. - ---cpu sets the default for the CPU type. The option takes a parameter, -which may be one of - - 6502, 65C02, 65816 and sunplus - -(the latter is not available in the freeware version). - ---pagelength sets the length of a listing page in lines. See the -.PAGELENGTH directive for more information. - ---smart is identical to -s - see there. +--------------------------------------------------------------------------- +Usage: ca65 [options] file +Short options: + -g Add debug info to object file + -h Help (this text) + -i Ignore case of symbols + -l Create a listing if assembly was ok + -o name Name the output file + -s Enable smart mode + -v Increase verbosity + -D name[=value] Define a symbol + -I dir Set an include directory search path + -U Mark unresolved symbols as import + -V Print the assembler version + -W n Set warning level n + +Long options: + --auto-import Mark unresolved symbols as import + --cpu type Set cpu type + --debug-info Add debug info to object file + --help Help (this text) + --ignore-case Ignore case of symbols + --include-dir dir Set an include directory search path + --listing Create a listing if assembly was ok + --pagelength n Set the page length for the listing + --smart Enable smart mode + --verbose Increase verbosity + --version Print the assembler version +--------------------------------------------------------------------------- + +Here is a description of all the command line options: + + + --cpu type + + Set the default for the CPU type. The option takes a parameter, which + may be one of + + 6502, 65C02, 65816 and sunplus + + (the latter is not available in the freeware version). + + + -g + --debug-info + + When this option (or the equivalent control command .DEBUGINFO) is used, + the assembler will add a section to the object file that contains all + symbols (including local ones) together with the symbol values and + source file positions. The linker will put these additional symbols into + the VICE label file, so even local symbols can be seen in the VICE + monitor. + + + -h + --help + + Print the short option summary shown above. + + + -i + --ignore-case + + This option makes the assembler case insensitive on identifiers and + labels. This option will override the default, but may itself be + overriden by the .CASE control command (see section 6). + + + -l + --listing + + Generate an assembler listing. The listing file will always have the + name of the main input file with the extension replaced by ".lst". This + may change in future versions. + + + -o name + + The default output name is the name of the input file with the extension + replaced by ".o". If you don't like that, you may give another name with + the -o option. The output file will be placed in the same directory as + the source file, or, if -o is given, the full path in this name is used. + + + --pagelength n + + sets the length of a listing page in lines. See the .PAGELENGTH + directive for more information. + + + -s + --smart-mode + + In smart mode (enabled by -s or the .SMART pseudo instruction) the + assembler will track usage of the REP and SEP instructions in 65816 mode + and update the operand sizes accordingly. If the operand of such an + instruction cannot be evaluated by the assembler (for example, because + the operand is an imported symbol), a warning is issued. + + Beware: Since the assembler cannot trace the execution flow this may + lead to false results in some cases. If in doubt, use the .ixx and .axx + instructions to tell the assembler about the current settings. Smart + mode is off by default. + + + -v + -verbose + + Increase the assembler verbosity. Usually only needed for debugging + purposes. You may use this option more than one time for even more + verbose output. + + + -D + + This option allows you to define symbols on the command line. Without a + value, the symbol is defined with the value zero. When giving a value, + you may use the '$' prefix for hexadecimal symbols. Please note that for + some operating systems, '$' has a special meaning, so you may have to + quote the expression. + + + -I dir + --include-dir dir + + Name a directory which is searched for include files. The option may be + used more than once to specify more than one directory to search. The + current directory is always searched first before considering any + additional directores. + + + -U + --auto-import + + Mark symbols that are not defined in the sources as imported symbols. + This should be used with care since it delays error messages about typos + and such until the linker is run. The compiler uses the equivalent of + this switch (.AUTOIMPORT, see control command section below) to enable + auto imported symbols for the runtime library. However, the compiler is + supposed to generate code that runs through the assembler without + problems, something which is not always true for assembler programmers. + + + -V + --version + + Print the version number of the assembler. If you send any suggestions + or bugfixes, please include the version number. + + + -Wn + + Set the warning level for the assembler. Using -W2 the assembler will + even warn about such things like unused imported symbols. The default + warning level is 1, and it would probably be silly to set it to + something lower. @@ -308,10 +383,13 @@ Available operators sorted by precedence: .CONST Builtin function 1 .CPU Builtin pseudo variable (r/o) 1 .DEFINED Builtin function 1 + .LEFT Builtin function 1 .MATCH Builtin function 1 + .MID Builtin function 1 .XMATCH Builtin function 1 .PARAMCOUNT Builtin pseudo variable (r/o) 1 .REFERENCED Builtin function 1 + .RIGHT Builtin function 1 .STRING Builtin function 1 :: Global namespace override 1 + Unary plus 1 @@ -331,7 +409,7 @@ Available operators sorted by precedence: << Shift left operator 2 .SHL Shift left operator 2 >> Shift right operator 2 - .SHR Shift right operator 2 + .SHR Shift right operator 2 + Binary plus 3 - Binary minus 3 @@ -1159,6 +1237,36 @@ Here's a list of all control commands and a description, what they do: .include "subs.inc" +.LEFT + + Builtin function. Extracts the left part of a given token list. + + Syntax: + + .LEFT (, ) + + The first integer expression gives the number of tokens to extract from + the token list. The second argument is the token list itself. + + Example: + + To check in a macro if the given argument has a '#' as first token + (immidiate addressing mode), use something like this: + + .macro ldax arg + ... + .if (.match (.left (1, arg), #)) + + ; ldax called with immidiate operand + ... + + .endif + ... + .endmacro + + See also the .MID and .RIGHT builtin functions. + + .LINECONT Switch on or off line continuations using the backslash character @@ -1325,6 +1433,39 @@ Here's a list of all control commands and a description, what they do: be the reserved keyword "A". +.MID + + Builtin function. Takes a starting index, a count and a token list as + arguments. Will return part of the token list. + + Syntax: + + .MID (, , ) + + The first integer expression gives the starting token in the list (the + first token has index 0). The second integer expression gives the number + of tokens to extract from the token list. The third argument is the + token list itself. + + Example: + + To check in a macro if the given argument has a '#' as first token + (immidiate addressing mode), use something like this: + + .macro ldax arg + ... + .if (.match (.mid (0, 1, arg), #)) + + ; ldax called with immidiate operand + ... + + .endif + ... + .endmacro + + See also the .LEFT and .RIGHT builtin functions. + + .ORG Start a section of absolute code. The command is followed by a constant @@ -1456,7 +1597,7 @@ Here's a list of all control commands and a description, what they do: storage should be defined. The second, optional expression must by a constant byte value that will be used as value of the data. If there is no fill value given, the linker will use the value defined in the - linker configuration file (default: zero). + linker configuration file (default: zero). Example: @@ -1464,6 +1605,20 @@ Here's a list of all control commands and a description, what they do: .res 12, $AA +.RIGHT + + Builtin function. Extracts the right part of a given token list. + + Syntax: + + .RIGHT (, ) + + The first integer expression gives the number of tokens to extract from + the token list. The second argument is the token list itself. + + See also the .LEFT and .MID builtin functions. + + .RODATA Switch to the RODATA segment. The name of the RODATA segment is always @@ -1821,7 +1976,7 @@ Macros with parameters may also be useful: .define DEBUG(message) .out message DEBUG "Assembling include file #3" - + Note that, while formal parameters have to be placed in braces, this is not true for the actual parameters. Beware: Since the assembler cannot detect the end of one parameter, only the first token is used. If you @@ -1896,9 +2051,9 @@ hear from you. Feel free to contact me by email (uz@musoftware.de). 10. Copyright ------------- -ca65 (and all cc65 binutils) are (C) Copyright 1998 Ullrich von Bassewitz. -For usage of the binaries and/or sources the following conditions do -apply: +ca65 (and all cc65 binutils) are (C) Copyright 1998-2000 Ullrich von +Bassewitz. For usage of the binaries and/or sources the following +conditions do apply: This software is provided 'as-is', without any expressed or implied warranty. In no event will the authors be held liable for any damages -- 2.39.5