]> git.sur5r.net Git - u-boot/blob - drivers/misc/cros_ec_lpc.c
arm: mvebu: Disable L2 cache before enabling d-cache
[u-boot] / drivers / misc / cros_ec_lpc.c
1 /*
2  * Chromium OS cros_ec driver - LPC interface
3  *
4  * Copyright (c) 2012 The Chromium OS Authors.
5  *
6  * SPDX-License-Identifier:     GPL-2.0+
7  */
8
9 /*
10  * The Matrix Keyboard Protocol driver handles talking to the keyboard
11  * controller chip. Mostly this is for keyboard functions, but some other
12  * things have slipped in, so we provide generic services to talk to the
13  * KBC.
14  */
15
16 #include <common.h>
17 #include <dm.h>
18 #include <command.h>
19 #include <cros_ec.h>
20 #include <asm/io.h>
21
22 #ifdef DEBUG_TRACE
23 #define debug_trace(fmt, b...)  debug(fmt, ##b)
24 #else
25 #define debug_trace(fmt, b...)
26 #endif
27
28 static int wait_for_sync(struct cros_ec_dev *dev)
29 {
30         unsigned long start;
31
32         start = get_timer(0);
33         while (inb(EC_LPC_ADDR_HOST_CMD) & EC_LPC_STATUS_BUSY_MASK) {
34                 if (get_timer(start) > 1000) {
35                         debug("%s: Timeout waiting for CROS_EC sync\n",
36                               __func__);
37                         return -1;
38                 }
39         }
40
41         return 0;
42 }
43
44 int cros_ec_lpc_command(struct udevice *udev, uint8_t cmd, int cmd_version,
45                      const uint8_t *dout, int dout_len,
46                      uint8_t **dinp, int din_len)
47 {
48         struct cros_ec_dev *dev = dev_get_uclass_priv(udev);
49         const int cmd_addr = EC_LPC_ADDR_HOST_CMD;
50         const int data_addr = EC_LPC_ADDR_HOST_DATA;
51         const int args_addr = EC_LPC_ADDR_HOST_ARGS;
52         const int param_addr = EC_LPC_ADDR_HOST_PARAM;
53
54         struct ec_lpc_host_args args;
55         uint8_t *d;
56         int csum;
57         int i;
58
59         if (dout_len > EC_PROTO2_MAX_PARAM_SIZE) {
60                 debug("%s: Cannot send %d bytes\n", __func__, dout_len);
61                 return -1;
62         }
63
64         /* Fill in args */
65         args.flags = EC_HOST_ARGS_FLAG_FROM_HOST;
66         args.command_version = cmd_version;
67         args.data_size = dout_len;
68
69         /* Calculate checksum */
70         csum = cmd + args.flags + args.command_version + args.data_size;
71         for (i = 0, d = (uint8_t *)dout; i < dout_len; i++, d++)
72                 csum += *d;
73
74         args.checksum = (uint8_t)csum;
75
76         if (wait_for_sync(dev)) {
77                 debug("%s: Timeout waiting ready\n", __func__);
78                 return -1;
79         }
80
81         /* Write args */
82         for (i = 0, d = (uint8_t *)&args; i < sizeof(args); i++, d++)
83                 outb(*d, args_addr + i);
84
85         /* Write data, if any */
86         debug_trace("cmd: %02x, ver: %02x", cmd, cmd_version);
87         for (i = 0, d = (uint8_t *)dout; i < dout_len; i++, d++) {
88                 outb(*d, param_addr + i);
89                 debug_trace("%02x ", *d);
90         }
91
92         outb(cmd, cmd_addr);
93         debug_trace("\n");
94
95         if (wait_for_sync(dev)) {
96                 debug("%s: Timeout waiting for response\n", __func__);
97                 return -1;
98         }
99
100         /* Check result */
101         i = inb(data_addr);
102         if (i) {
103                 debug("%s: CROS_EC result code %d\n", __func__, i);
104                 return -i;
105         }
106
107         /* Read back args */
108         for (i = 0, d = (uint8_t *)&args; i < sizeof(args); i++, d++)
109                 *d = inb(args_addr + i);
110
111         /*
112          * If EC didn't modify args flags, then somehow we sent a new-style
113          * command to an old EC, which means it would have read its params
114          * from the wrong place.
115          */
116         if (!(args.flags & EC_HOST_ARGS_FLAG_TO_HOST)) {
117                 debug("%s: CROS_EC protocol mismatch\n", __func__);
118                 return -EC_RES_INVALID_RESPONSE;
119         }
120
121         if (args.data_size > din_len) {
122                 debug("%s: CROS_EC returned too much data %d > %d\n",
123                       __func__, args.data_size, din_len);
124                 return -EC_RES_INVALID_RESPONSE;
125         }
126
127         /* Read data, if any */
128         for (i = 0, d = (uint8_t *)dev->din; i < args.data_size; i++, d++) {
129                 *d = inb(param_addr + i);
130                 debug_trace("%02x ", *d);
131         }
132         debug_trace("\n");
133
134         /* Verify checksum */
135         csum = cmd + args.flags + args.command_version + args.data_size;
136         for (i = 0, d = (uint8_t *)dev->din; i < args.data_size; i++, d++)
137                 csum += *d;
138
139         if (args.checksum != (uint8_t)csum) {
140                 debug("%s: CROS_EC response has invalid checksum\n", __func__);
141                 return -EC_RES_INVALID_CHECKSUM;
142         }
143         *dinp = dev->din;
144
145         /* Return actual amount of data received */
146         return args.data_size;
147 }
148
149 /**
150  * Initialize LPC protocol.
151  *
152  * @param dev           CROS_EC device
153  * @param blob          Device tree blob
154  * @return 0 if ok, -1 on error
155  */
156 int cros_ec_lpc_init(struct cros_ec_dev *dev, const void *blob)
157 {
158         int byte, i;
159
160         /* See if we can find an EC at the other end */
161         byte = 0xff;
162         byte &= inb(EC_LPC_ADDR_HOST_CMD);
163         byte &= inb(EC_LPC_ADDR_HOST_DATA);
164         for (i = 0; i < EC_PROTO2_MAX_PARAM_SIZE && (byte == 0xff); i++)
165                 byte &= inb(EC_LPC_ADDR_HOST_PARAM + i);
166         if (byte == 0xff) {
167                 debug("%s: CROS_EC device not found on LPC bus\n",
168                         __func__);
169                 return -1;
170         }
171
172         return 0;
173 }
174
175 /*
176  * Test if LPC command args are supported.
177  *
178  * The cheapest way to do this is by looking for the memory-mapped
179  * flag.  This is faster than sending a new-style 'hello' command and
180  * seeing whether the EC sets the EC_HOST_ARGS_FLAG_FROM_HOST flag
181  * in args when it responds.
182  */
183 static int cros_ec_lpc_check_version(struct udevice *dev)
184 {
185         if (inb(EC_LPC_ADDR_MEMMAP + EC_MEMMAP_ID) == 'E' &&
186                         inb(EC_LPC_ADDR_MEMMAP + EC_MEMMAP_ID + 1)
187                                 == 'C' &&
188                         (inb(EC_LPC_ADDR_MEMMAP +
189                                 EC_MEMMAP_HOST_CMD_FLAGS) &
190                                 EC_HOST_CMD_FLAG_LPC_ARGS_SUPPORTED)) {
191                 return 0;
192         }
193
194         printf("%s: ERROR: old EC interface not supported\n", __func__);
195         return -1;
196 }
197
198 static int cros_ec_probe(struct udevice *dev)
199 {
200         return cros_ec_register(dev);
201 }
202
203 static struct dm_cros_ec_ops cros_ec_ops = {
204         .command = cros_ec_lpc_command,
205         .check_version = cros_ec_lpc_check_version,
206 };
207
208 static const struct udevice_id cros_ec_ids[] = {
209         { .compatible = "google,cros-ec-lpc" },
210         { }
211 };
212
213 U_BOOT_DRIVER(cros_ec_lpc) = {
214         .name           = "cros_ec_lpc",
215         .id             = UCLASS_CROS_EC,
216         .of_match       = cros_ec_ids,
217         .probe          = cros_ec_probe,
218         .ops            = &cros_ec_ops,
219 };