]> git.sur5r.net Git - u-boot/commit
omap: overo: Disable pull-ups on camera PCLK, HS and VS signals
authorSteve Sakoman <sakoman@gmail.com>
Fri, 30 Sep 2011 09:08:36 +0000 (09:08 +0000)
committerAlbert ARIBAUD <albert.u.boot@aribaud.net>
Thu, 27 Oct 2011 19:56:34 +0000 (21:56 +0200)
commit353ffa7f93ab90655af2b194b7d0d16f106c297c
tree2da82ab19b593cf6999371014917ae585c3f96a7
parent14aa545c45f3f6d487c83b4fc3be19dd9f9e4e5b
omap: overo: Disable pull-ups on camera PCLK, HS and VS signals

The level shifters used on the Caspa camera module have a 4k output
impedance. Combined with the 100uA pull-up resistors in the OMAP3,
this raises the ground level to 400mV. Adding crosstalk between the
pixel clock and the HS/VS signals on the flat cable (a ground line in
between would have been nice), logic 0 levels can raise up to 650mV.
This exceeds the camera input pins VIL maximum voltage.  This change
suggested-by Laurent Pinchart

Signed-off-by: Steve Sakoman <steve@sakoman.com>
Signed-off-by: Sandeep Paulraj <s-paulraj@ti.com>
board/overo/overo.h