]> git.sur5r.net Git - u-boot/commit
x86: quark: Initialize thermal sensor properly
authorBin Meng <bmeng.cn@gmail.com>
Thu, 10 Sep 2015 06:20:27 +0000 (23:20 -0700)
committerSimon Glass <sjg@chromium.org>
Thu, 17 Sep 2015 01:53:53 +0000 (19:53 -0600)
commit554778c240385b09dc01140865fe3f5d04806456
tree29a2a344f00b40a7aca4c7e1d7e8e938fb2f8949
parent693b5f6c71c870276f5c370254fafcb10ee43cb1
x86: quark: Initialize thermal sensor properly

Thermal sensor on Quark SoC needs to be properly initialized per
Quark firmware writer guide, otherwise when booting Linux kernel,
it triggers system shutdown because of wrong temperature in the
thermal sensor is detected by the kernel driver (see below):

[    5.119819] thermal_sys: Critical temperature reached(206 C),shutting down
[    5.128997] Failed to start orderly shutdown: forcing the issue
[    5.135495] Emergency Sync complete

Signed-off-by: Bin Meng <bmeng.cn@gmail.com>
Acked-by: Simon Glass <sjg@chromium.org>
arch/x86/cpu/quark/quark.c
arch/x86/include/asm/arch-quark/quark.h