The sun8i-emac driver follows an old version of the proposed DT
bindings, where the EMAC clock and EPHY control register range is
listed directly, rather than through a syscon phandle.
Add back the syscon register range to avoid an invalid data access.
We should fix the driver once the Linux kernel bindings have been
finalized.
Signed-off-by: Chen-Yu Tsai <wens@csie.org> Reviewed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>