In e1000e driver, Rx descriptor queue is used such that hardware can add only
one descriptor at a time. So the WTHRESH granularity in RXDCTL should be set
to single descriptor. This would ensure that every time controller fills a Rx
descriptor, it is flushed to host memory. Earlier this granularity was in
cache line units i.e 2 descriptors. This leads to controller always waiting
for 2 descriptors before flushing them out. But since not more than one Rx BD
is actually available , the accumulation condition never gets hit.