This patch changed the datatype of variable "start" from uint to ulong
to work properly on 64-bit machines as well. Also the return type of
get_timer() function is ulong.
Signed-off-by: Vipul Kumar <vipul.kumar@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
{
struct mmc_cmd cmd;
int timeout = 1000;
- uint start;
+ ulong start;
int err;
mmc->op_cond_pending = 0;
int mmc_init(struct mmc *mmc)
{
int err = 0;
- __maybe_unused unsigned start;
+ __maybe_unused ulong start;
#if CONFIG_IS_ENABLED(DM_MMC)
struct mmc_uclass_priv *upriv = dev_get_uclass_priv(mmc->dev);
u32 mask, flags, mode;
unsigned int time = 0, start_addr = 0;
int mmc_dev = mmc_get_blk_desc(mmc)->devnum;
- unsigned start = get_timer(0);
+ ulong start = get_timer(0);
/* Timeout unit - ms */
static unsigned int cmd_timeout = SDHCI_CMD_DEFAULT_TIMEOUT;