Testing shows, that PHY polling needs to be enabled on Armada 7k/8k.
Otherwise ethernet transfers will not work correctly. PHY polling
is enabled per default after reset, so we do not need to specifically
enable it, but this makes it clearer.
Signed-off-by: Stefan Roese <sr@denx.de>
Cc: Stefan Chulski <stefanc@marvell.com>
Cc: Kostya Porotchkin <kostap@marvell.com>
Cc: Nadav Haklai <nadavh@marvell.com>
Acked-by: Joe Hershberger <joe.hershberger@ni.com>
if (priv->hw_version == MVPP22)
mvpp2_axi_init(priv);
- /* Disable HW PHY polling */
if (priv->hw_version == MVPP21) {
+ /* Disable HW PHY polling */
val = readl(priv->lms_base + MVPP2_PHY_AN_CFG0_REG);
val |= MVPP2_PHY_AN_STOP_SMI0_MASK;
writel(val, priv->lms_base + MVPP2_PHY_AN_CFG0_REG);
} else {
+ /* Enable HW PHY polling */
val = readl(priv->iface_base + MVPP22_SMI_MISC_CFG_REG);
- val &= ~MVPP22_SMI_POLLING_EN;
+ val |= MVPP22_SMI_POLLING_EN;
writel(val, priv->iface_base + MVPP22_SMI_MISC_CFG_REG);
}