With commit 
e3a77218a256edbe201112a39beeed8adcabae3f the MII bus is only
reset if a reset handler is registered. If there is no reset handler there
is no need to wait for a device to come out of the reset.
Signed-off-by: Jörg Krause <joerg.krause@embedded.rocks>
                phy_interface_t interface)
 {
        /* Reset the bus */
-       if (bus->reset)
+       if (bus->reset) {
                bus->reset(bus);
 
-       /* Wait 15ms to make sure the PHY has come out of hard reset */
-       udelay(15000);
+               /* Wait 15ms to make sure the PHY has come out of hard reset */
+               udelay(15000);
+       }
+
        return get_phy_device_by_mask(bus, phy_mask, interface);
 }