dm_serial_ops.pending should return the number of characters, not just a
valid C Boolean integer value. The existing code does already does this,
but only as an accident since BCM283X_MU_LSR_RX_READY happens to be
BIT(0). Enhance the code to be more explicit about the values it returns.
Suggested-by: Simon Glass <sjg@chromium.org>
Signed-off-by: Stephen Warren <swarren@wwwdotorg.org>
 
        if (input) {
                WATCHDOG_RESET();
-               return lsr & BCM283X_MU_LSR_RX_READY;
+               return (lsr & BCM283X_MU_LSR_RX_READY) ? 1 : 0;
        } else {
-               return !(lsr & BCM283X_MU_LSR_TX_IDLE);
+               return (lsr & BCM283X_MU_LSR_TX_IDLE) ? 0 : 1;
        }
 }