A-007186: SerDes PLL is calibrated at reset. It is possible
for jitter to increase and cause the PLL to unlock when the
temperature delta from the time the PLL is calibrated exceeds
+56C/-66C when using X VDD of 1.35 V (or +70C/-80C when using
XnVDD of 1.5 V). No issues are seen with LC VCO. The protocols
only using Ring VCOs are impacted.
Workaround:
For all 1.25/2.5/5 GHz protocols, use LC VCO instead of Ring
VCO, this need to use alternate serdes protocols. Alternate
option has the same functionality as the original option; the
only difference being LC VCO rather than Ring VCO.
Signed-off-by: Chunhe Lan <Chunhe.Lan@freescale.com>
Reviewed-by: York Sun <yorksun@freescale.com>
/* Register the 10G MDIO bus */
fm_memac_mdio_init(bis, &tgec_mdio_info);
- if (srds_prtcl_s1 == 28) {
+ if ((srds_prtcl_s1 == 28) || (srds_prtcl_s1 == 27)) {
/* SGMII */
fm_info_set_phy_address(FM1_DTSEC1, SGMII_PHY_ADDR1);
fm_info_set_phy_address(FM1_DTSEC2, SGMII_PHY_ADDR2);
#PBL preamble and RCW header
aa55aa55 010e0100
-#serdes protocol 28_56_2_10
+#serdes protocol 27_56_1_9
16070019 18101916 00000000 00000000
-70701050 00448c00 6c020000 f5000000
+6c700848 00448c00 6c020000 f5000000
00000000 ee0000ee 00000000 000287fc
00000000 50000000 00000000 00000028