+S:CONFIG_AXP221_DLDO1_VOLT=3300
# Wifi power
+S:CONFIG_AXP221_ALDO1_VOLT=3300
-# HDMI power ?
-+S:CONFIG_AXP221_ALDO2_VOLT=1800
-+S:CONFIG_AXP221_ALDO3_VOLT=3000
# No Vbus gpio for either usb
+S:CONFIG_USB1_VBUS_PIN=""
+S:CONFIG_USB2_VBUS_PIN=""
+S:CONFIG_DRAM_ZQ=251
# Wifi power
+S:CONFIG_AXP221_ALDO1_VOLT=3300
-# HDMI power ?
-+S:CONFIG_AXP221_ALDO2_VOLT=1800
-+S:CONFIG_AXP221_ALDO3_VOLT=3000
# No Vbus gpio for usb1
+S:CONFIG_USB1_VBUS_PIN=""
+S:CONFIG_DRAM_ZQ=251
# Wifi power
+S:CONFIG_AXP221_ALDO1_VOLT=3300
-# PM-CPUS GPIO power
-+S:CONFIG_AXP221_ALDO2_VOLT=1800
-# SoC IR, PLL and Analog power (must be 3.0V)
-+S:CONFIG_AXP221_ALDO3_VOLT=3000
# Vbus gpio for usb1
+S:CONFIG_USB1_VBUS_PIN="PH24"
# No Vbus gpio for usb2
+S:CONFIG_AXP221_DLDO4_VOLT=3300
# Wifi power
+S:CONFIG_AXP221_ALDO1_VOLT=3300
-# HDMI power ?
-+S:CONFIG_AXP221_ALDO2_VOLT=1800
-+S:CONFIG_AXP221_ALDO3_VOLT=3000
# Vbus gpio for usb1
+S:CONFIG_USB1_VBUS_PIN="PC27"
# No Vbus gpio for usb2
default -1
---help---
Set the voltage (mV) to program the axp221 dldo1 at, set to -1 to
- disable dldo1.
+ disable dldo1. On sun6i (A31) boards with ethernet this is often used
+ to power the ethernet phy. On sun8i (A23) boards this is often used to
+ power the wifi.
config AXP221_DLDO4_VOLT
int "axp221 dldo4 voltage"
default -1
---help---
Set the voltage (mV) to program the axp221 aldo1 at, set to -1 to
- disable aldo1.
+ disable aldo1. On sun6i (A31) boards which have a wifi module this is
+ often used to power the wifi module.
config AXP221_ALDO2_VOLT
int "axp221 aldo2 voltage"
depends on AXP221_POWER
- default -1
+ default 1800 if MACH_SUN6I
+ default 2500 if MACH_SUN8I
---help---
Set the voltage (mV) to program the axp221 aldo2 at, set to -1 to
- disable aldo2.
+ disable aldo2. On sun6i (A31) boards this is typically connected to
+ VCC-PM, which powers the port M gpios, and should be set to 1.8V.
+ On sun8i (A23) this is typically connected to VDD-DLL and must be
+ set to 2.5V.
config AXP221_ALDO3_VOLT
int "axp221 aldo3 voltage"
depends on AXP221_POWER
- default -1
+ default 3000
---help---
Set the voltage (mV) to program the axp221 aldo3 at, set to -1 to
- disable aldo3.
+ disable aldo3. This is typically connected to VCC-PLL and AVCC and
+ must be set to 3V.