As per JEDEC document JESD84-A441 (page 105) response for CMD7
(MMC_CMD_SELECT_CARD) response should be R1 instead of R1b. In uboot we
never take MMC to disconnected state and on powerup its always ideal
state which later goes to stand-by state.
from document footnote:
R1 while selecting from Stand-By State to Transfer State; R1b while
selecting from Disconnected State to Programming State.
Signed-off-by: Ajay Bhargav <ajay.bhargav@einfochips.com>
/* Select the card, and put it into Transfer Mode */
if (!mmc_host_is_spi(mmc)) { /* cmd not supported in spi */
cmd.cmdidx = MMC_CMD_SELECT_CARD;
- cmd.resp_type = MMC_RSP_R1b;
+ cmd.resp_type = MMC_RSP_R1;
cmd.cmdarg = mmc->rca << 16;
cmd.flags = 0;
err = mmc_send_cmd(mmc, &cmd, NULL);