3 #define VERSION "5.1.7"
4 #define BDATE "24 July 2010"
5 #define LSMDATE "24Jul10"
7 #define PROG_COPYRIGHT "Copyright (C) %d-2010 Free Software Foundation Europe e.V.\n"
8 #define BYEAR "2010" /* year for copyright messages in progs */
11 Bacula® - The Network Backup Solution
13 Copyright (C) 2000-2010 Free Software Foundation Europe e.V.
15 The main author of Bacula is Kern Sibbald, with contributions from
16 many others, a complete list can be found in the file AUTHORS.
17 This program is Free Software; you can redistribute it and/or
18 modify it under the terms of version three of the GNU Affero General Public
19 License as published by the Free Software Foundation and included
22 This program is distributed in the hope that it will be useful, but
23 WITHOUT ANY WARRANTY; without even the implied warranty of
24 MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
25 General Public License for more details.
27 You should have received a copy of the GNU Affero General Public License
28 along with this program; if not, write to the Free Software
29 Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
32 Bacula® is a registered trademark of Kern Sibbald.
34 The licensor of Bacula is the Free Software Foundation Europe
35 (FSFE), Fiduciary Program, Sumatrastrasse 25, 8006 Zürich,
36 Switzerland, email:ftf@fsfeurope.org.
39 /* Shared object library versions */
41 /* Uncomment to overwrite default value from VERSION */
42 /* #define LIBBAC_LT_RELEASE "5.1.0" */
43 /* #define LIBBACCFG_LT_RELEASE "5.1.0" */
44 /* #define LIBBACPY_LT_RELEASE "5.1.0" */
45 /* #define LIBBACSQL_LT_RELEASE "5.1.0" */
46 /* #define LIBBACFIND_LT_RELEASE "5.1.0" */
55 /* If this is set stdout will not be closed on startup */
59 * SMCHECK does orphaned buffer checking (memory leaks)
60 * it can always be turned on, but has some minor performance
68 * _USE_LOCKMGR does lock/unlock mutex tracking (dead lock)
69 * it can always be turned on, but we advise to use it only
75 # endif /* _USE_LOCKMGR */
77 * Enable priority management with the lock manager
79 * Note, turning this on will cause the Bacula SD to abort if
80 * mutexes are executed out of order, which could lead to a
81 * deadlock. However, note that this is not necessarily a
82 * deadlock, so turn this on only for debugging.
84 #define USE_LOCKMGR_PRIORITY
87 * Enable thread verification before kill
89 * Note, this extra check have a high cost when using
90 * dozens of thread, so turn this only for debugging.
92 /* #define USE_LOCKMGR_SAFEKILL */
93 #endif /* DEVELOPER */
95 #if !HAVE_LINUX_OS && !HAVE_SUN_OS && !HAVE_DARWIN_OS && !HAVE_FREEBSD_OS
100 * USE_VTAPE is a dummy tape driver. This is useful to
108 * for fastest speed but you must have a UPS to avoid unwanted shutdowns
110 //#define SQLITE3_INIT_QUERY "PRAGMA synchronous = OFF"
113 * for more safety, but is 30 times slower than above
115 #define SQLITE3_INIT_QUERY "PRAGMA synchronous = NORMAL"
118 * This should always be on. It enables data encryption code
119 * providing it is configured.
121 #define DATA_ENCRYPTION 1
124 * This uses a Bacula specific bsnprintf rather than the sys lib
125 * version because it is much more secure. It should always be
128 #define USE_BSNPRINTF 1
130 /* Debug flags not normally turned on */
132 /* #define TRACE_JCR_CHAIN 1 */
133 /* #define TRACE_RES 1 */
134 /* #define DEBUG_MEMSET 1 */
135 /* #define DEBUG_MUTEX 1 */
139 * Set SMALLOC_SANITY_CHECK to zero to turn off, otherwise
140 * it is the maximum memory malloced before Bacula will
141 * abort. Except for debug situations, this should be zero
143 #define SMALLOC_SANITY_CHECK 0 /* 500000000 0.5 GB max */
146 /* Check if header of tape block is zero before writing */
147 /* #define DEBUG_BLOCK_ZEROING 1 */
149 /* #define FULL_DEBUG 1 */ /* normally on for testing only */
151 /* Turn this on ONLY if you want all Dmsg() to append to the
152 * trace file. Implemented mainly for Win32 ...
154 /* #define SEND_DMSG_TO_FILE 1 */
157 /* The following are turned on for performance testing */
159 * If you turn on the NO_ATTRIBUTES_TEST and rebuild, the SD
160 * will receive the attributes from the FD, will write them
161 * to disk, then when the data is written to tape, it will
162 * read back the attributes, but they will not be sent to
163 * the Director. So this will eliminate: 1. the comm time
164 * to send the attributes to the Director. 2. the time it
165 * takes the Director to put them in the catalog database.
167 /* #define NO_ATTRIBUTES_TEST 1 */
170 * If you turn on NO_TAPE_WRITE_TEST and rebuild, the SD
171 * will do all normal actions, but will not write to the
172 * Volume. Note, this means a lot of functions such as
173 * labeling will not work, so you must use it only when
174 * Bacula is going to append to a Volume. This will eliminate
175 * the time it takes to write to the Volume (not the time
176 * it takes to do any positioning).
178 /* #define NO_TAPE_WRITE_TEST 1 */
181 * If you turn on FD_NO_SEND_TEST and rebuild, the FD will
182 * not send any attributes or data to the SD. This will
183 * eliminate the comm time sending to the SD.
185 /* #define FD_NO_SEND_TEST 1 */