]> git.sur5r.net Git - bacula/bacula/blobdiff - bacula/ReleaseNotes
- Comment out Multiple Connections in the document.
[bacula/bacula] / bacula / ReleaseNotes
index a644726239fb520084aa3d328e1c23d4d509114c..13e985bfe604834704970a06c9fac359db6fedcf 100644 (file)
 
-          Release Notes for Bacula 1.33.4
-
-  Bacula code: Total files = 306 Total lines = 90,715 (*.h *.c *.in)
-
-Major Features:
-- Data spooling which eliminates tape shoe-shine during Inc backups,         
-  and permits multiple simultaneous backups without interleaved blocks.
-- Native Win32 client -- much faster and restores permissions correctly
-  (thanks to Christopher Hull)
-- PostgreSQL database driver (thanks to Dan Langille).
-- Polling of devices eliminating need to unmount and mount from
-  console.
-- Improved Autochange support of Slots (update slots scan).
-- Autochanger support for multiple drives.
-- New conio code to implement Console command line editing and history.
-- JobDefs resource permits smaller .conf files for Director
-- Access console lists for the Console
-- Pool level overrides.
-- Daemon statistics memory.
-- Improved btape "test" and "fill" commands.
-
-
-Items to note:  !!!!!
-- The restore default is changed to have nothing selected by default.
-  You must either enter: "restore all" or after getting into the tree
-  selection prompt enter "mark *" to have everything selected.
-- In previous versions the "all" keyword on the restore command caused
-  it to return without user interaction after selecting everything. 
-  This function is now replaced by the "done" keyword (more logical).
-  The "all" keyword now causes everything to be selected by default.
-- The default tape driver behavior is now to write only a single EOF
-  at the end of the tape. For most tape drives, this is totally            
-  transparent and nothing needs to be done. For FreeBSD see below.
-- FreeBSD users NOTE!!!!!
-  You MUST add the following two records to your SD Device resource for
-  tape drives.
-
-     TWOEOF = yes
-     Fast Forward Space File = no
-
-- The daemon protocol has changed, you must update everything at once.
-- The database level has been updated. You must either re-initialize
-  your databases with:
-   
-    ./drop_bacula_tables
-    ./make_bacula_tables
-
-  which will delete ALL prior catalog information, or you can
-  update your database with:
-
-    ./update_bacula_tables
-
-  Please save your old database before dropping the tables or doing
-  an upgrade or you may regret it later.
-
-- smtp has now become bsmtp -- you *must* modify your .conf files.
-- console has now become bconsole.
-- console.conf is now bconsole.conf
-- Please don't underestimate the repercussions of the bsmtp and bconsole 
-  name changes!
-
-
-New directives:
-- "Close on Poll = yes/no" in SD Device resource.
-- "Volume Poll Interval = time-interval" in SD Device resource.
-- "Two EOF = yes/no" in SD Device resource.
-- "Maximum Network Buffer Size = size" in SD Device resource.
-- "Maximum Network Buffer Size = size" in FD FileDaemon (or Client) resource.
-- "Console" new resource in Director conf file.
-     New directives: Name, Description, Password, JobACL, ClientACL,
-        StorageACL, ScheduleACL, RunACL, PoolACL, CommandACL,
-        FileSetACL, CatalogACL.
-- "Max Run Time = duration" in Director Job resource.
-- "Max Wait Time = duration" in Director Job resource (not fully implemented).
-- "JobDefs = name-of-resource" in Director Job resource.
-- "Jobdefs" new resource in Director. Same directives as for a Job.
-- "Full Backup Pool = xxx" in Job resource in the Director.
-- "Incremental Backup Pool = xxx" in Job resource in the Director.
-- "Differential Backup Pool = xxx" in Job resource in the Director.
-- Three new options on the Run override statement in a Schedule resource:
-   FullPool=xxx
-   IncrementalPool=xxx
-   DifferentialPool=xxx
-- SpoolData=yes/no in DIR Job resource
-- SpoolData=yes/no in Run override directive.
-- MaximumSpoolSize in SD Device resource
-- MaximumSpoolJobSize in SD Device resource
-- SpoolDirectory in SD Device resource.
+          Release Notes for Bacula 1.37.6
+
+  Bacula code: Total files = 414 Total lines = 123,723 (*.h *.c *.in)
+
+
+Major Changes:
+- This version has a new database format that is not compatible
+  with previous databases. The upgrade scripts should work, but
+  they are not yet tested.
+- SQLite3 support, but it seems to run at 1/2 to 1/4 the speed of
+  SQLite2.
+- First cut at ANSI labels.
+- New communications protocol between DIR and SD to reserve 
+  drives. The DIR and SD are no longer compatible with 1.36 or
+  lower versions.
+- Preliminary Python Event support has been added. See below for
+  configuration and details.
+- DVD writing support, using parts, and a lot of new directives in
+  the Device resource of the Storage configuration file.
+- Seven new options keywords in a FileSet resource:
+  ignorecase, fstype, hfsplussupport, wilddir, wildfile, regexdir,
+  and regexfile. See below for details.
+
+New Directives:
+- New Run directive in Job resource of DIR. It permits
+  cloning of jobs.  To clone a copy of the current job, use
+     Run = "job-name level=%l since=\"%s\""
+  Note, job-name is normally the same name as the job that
+  is running but there is no restriction on what you put. If you
+  want to start the job by hand and use job overrides such as       
+  storage=xxx, realize that the job will be started with the
+  default storage values not the overrides.  The level=%l guarantees
+  that the chosen level of the job is the same, and the since=... 
+  ensures that the job uses *exactly* the same time/date for incremental
+  and differential jobs. The since=... is ignored when level=Full.
+  A cloned job will not start additional clones, so it is not possible
+  to recurse.
+- New Options keywords in a FileSet directive:
+  - WildDir xxx
+    Will do a wild card match against directories (files will not
+    be matched).
+  - WildFile xxx
+    Will do a wild card match against files (directories will not
+    be matched).
+  - RegexDir xxx
+    Will do a regular expression match against directories (files
+    will not be matched).
+  - RegexFile xxx
+    Will do a regular expression match against files( directories
+    will not be matched).
+  - IgnoreCase = yes | no
+    Will ignore case in wild card and regular expression matches.
+    This is handy for Windows where filename case is not significant.
+  - FsType = string
+    where string is a filesystem type: ext2, jfs, ntfs, proc,
+    reiserfs, xfs, usbdevfs, sysfs, smbfs, iso9660.  For ext3
+    systems, use ext2.  You may have multiple fstype directives
+    and thus permit multiple filesystem types.  If the type
+    specified on the fstype directive does not match the
+    filesystem for a particular directive, that directory will
+    not be backed up.  This directive can be used to prevent
+    backing up non-local filesystems.
+  - HFS Plus Support = yes | no 
+    If set, Mac OS X resource forks will be saved and restored.
+- Label Type = ANSI | IBM | Bacula   
+  Implemented in Director Pool resource and in SD Device resource.
+  If it is specified in the SD Device resource, it will take
+  precedence over the value passed from the Director to the SD.
+  IBM is not yet implemented.
+- Check Labels = yes | no
+  Implemented in the SD Device resource. If you intend to read
+  ANSI or IBM labels, this *must* be set. Even if the volume
+  is not ANSI labeled, you can set this to yes, and Bacula will
+  check the label type.
+- Scripts Directory = <directory> name.  Defines the directory from 
+  which Bacula scripts will be called for events. In fact, Bacula
+  appends this name to the standard Python list of search directories,
+  so the script could also be in any of the Python system directories.
+- In FileSet, you can exclude backing up of hardlinks (if you have
+  a lot, it can be very expensive), by using:
+    HardLinks = no
+  in the Options section. Patch supplied by David R Bosso. Thanks.
+- MaximumPartSize = bytes (SD, Device resource)
+  Defines the maximum part size.
+- Requires Mount = Yes/No (SD, Device resource)
+  Defines if the device require to be mounted to be read, and if it
+  must be written in a special way. If it set, the following directives 
+  must be defined in the same Device resource:
+  + Mount Point = directory
+    Directory where the device must be mounted. 
+  + Mount Command = name-string
+    Command that must be executed to mount the device. Before the command
+    is executed, %a is replaced with the Archive Device, and %m with the 
+    Mount Point.
+  + Unmount Command = name-string
+    Command that must be executed to unmount the device. Before the 
+    command is executed, %a is replaced with the Archive Device, and 
+    %m with the Mount Point.
+  + Write Part Command = name-string
+    Command that must be executed to write a part to the device. Before
+    the command is executed, %a is replaced with the Archive Device, %m 
+    with the Mount Point, %n with the current part number (0-based), 
+    and %v with the current part filename.
+  + Free Space Command = name-string
+    Command that must be executed to check how much free space is left 
+    on the device. Before the command is executed, %a is replaced with 
+    the Archive Device, %m with the Mount Point, %n with the current part
+    number (0-based), and %v with the current part filename.
+- Write Part After Job = Yes/No (DIR, Job Resource, and Schedule Resource)
+  If this directive is set to yes (default no), a new part file will be
+  created after the job is finished.
 
 New Commands:
-- "SetIP"
-- Added "pool=xxx" to restore command line.
-- Added "fileset=xxx" to restore command line.
-- Fixed "storage=xxx" on restore command line.
-- "markdir" command in restore tree.
-- "unmarkdir" command in restore tree.
-- "quit" command in restore tree.
-- Trace option on "setdebug trace=1/0 ..."
-- Update slots scan
-- The "all" keyword on the restore command marks all files by default.
-- The "done" keyword prevents user interaction with the tree -- used
-  mostly for batch scripting.
-
-
-Additional changes:
-- Implement Gnome 2.0 restore GUI
-- Add a missing unlock in the jobq handler.
-- Fix bug where a soft linked file and a directory had the same name
-  by treating the soft link as a directory and putting the entries under
-  it. This fixes the bug reported by Alexander Mueller.
-- Apply Jess Guardiani's second fix to list autochanger volumes without
-  opening the drive (necessary on FreeBSD if no tape is in the drive).
-- Reworked the command line handler in restore to walk through the
-  arguments one at a time. This makes the file= entries work correctly.
-  Also reworked the code that takes the MediaType and finds a 
-  storage device.
-- Add quit command to restore tree handler.
-- Make restore tree handler remember if a hard link is present, and
-  in doing a mark, only get database entry if there is a hard link.
-  mark commands thus run at least 2 orders of magnitude faster.
-- Add files=xxx field to run command submitted for restore.   
-- Add yes to restore run command if either yes or run is command line
-  argument.
-- Make "yes" on command line argument skip prompt for modification of
-  run job.
-- Add markdir and unmarkdir -- both affect only the directory in
-  question and do not do a recursive descent.
-- Make tree command automatically mark all higher level directories to
-  be restored when a directory or a file is selected.  Such directories
-  are indicated by preceding the name with a + to indicate that only
-  the directory entry is selected and not the whole directory tree.
-- Modify a few tree commands to walk through all arguments rather than
-  just taking the first one.
-- Improved btape "test" and "fill" commands.
-- The ability to ask the Storage daemon on a device by device basis
-  to "poll" the tape drive at a given interval (minimum 1 minute). If
-  a tape is found, its label is read and if appropriate it is used.
-  This eliminates the need to do "mount" commands.
-- The ability to close and re-open the device when a poll occurs. 
-  This permits dealing with certain recalcitrant autochangers that
-  invalidate devices (typically on FreeBSD).
-- Dan Langille has written a PostgreSQL driver for Bacula.
-- Implement "update slots scan" that reads the volume label(s).
-- The full form of the scan is "scan=1,2,4-5,7". With no specification,
-  all occupied slots are scanned.
-- Turn off changer Volumes that are not current in the changer when
-  an "update slots" is done, or if any tape operation discovers that
-  the right volume is not in the slot.
-- The console program will run all commands it finds in ~/.bconsolerc
-  at startup.
-- Add Dan Langille's changes to the bacula start/stop script that 
-  permit dropping root permissions just after startup.
-- New version 1.5.5-1 Cygwin.
-- Modify SD to update the catalog database when it is shutdown,
-  even if the job is canceled.
-- Fixed seg fault in restore of multiple simultaneous jobs to 
-  a single Volume.
-- Fixed thread race problem in multiple simultaneous jobs to
-  a single Volume where the volume label is not in the first 
-  tape block, so the tape is not recognized.
-- Restore directory tree automatically selects all higher level
-  directories to be restored.
-- Implement conio.c to use in console program -- mini-readline.
-- Enhance "fill" command of btape -- simpler output. Use -v to
-  cause last block to be dumped after write and after re-read.
-- Added an autochanger test to the btape "test" command. It is 
-  automatically invoked if the autochanger is properly configured.  It
-  is still a bit primitive but covers the essential of testing
-  the mtx-changer script with your autochanger.
-- Select the oldest LastWritten volume during recycling.
-- Added forward space file test to btape "test" command.
-- All 1.32d patches applied.
-- Fixed seg fault in restore of multiple simultaneous jobs to 
-  a single Volume.
-- Fixed thread race problem in multiple simultaneous jobs to
-  a single Volume where the volume lable is not in the first 
-  tape block, so the tape is not recognized.
+- "python restart" restarts the Python interpreter. Rather brutal, make
+   sure no Python scripts are running. This permits you to change
+   a Python script and get Bacula to use the new script.
+
+Items to note!!!
+- You must add --with-python=[DIR] to the configure command line
+  if you want Python support.  Python 2.2 and 2.3 should be automatically
+  detected if in the standard place.
+- With Python 2.2 version, the link of the Director gets a few linker
+  warnings due to the fact that Python pulls in some old non-secure
+  libraries.
+- With Python 2.3, there are a few compiler warnings.
+- You must either create a new catalog database or upgrade your
+  old database (upgrade scripts not yet tested).
+
+Other Items:
+- 2 new scripts, dvd-writepart and dvd-freespace, in the scripts directory,
+  which are designed to be used as parameters to Write Part Command and
+  Free Space Command. They need the dvd+rw-tools to be installed
+  (http://fy.chalmers.se/~appro/linux/DVD+RW/).
+- Part files support: File volumes can now be splitted in multiple
+  files, called "parts".
+- Python scripting support:
+  A Python script will be called at particular points or conditions
+  in Bacula called Events. The currently defined Events are called:
+
+  StartJob, EndJob, NewVolume
+
+  Where StartJob is called before the RunBeforeJob, EndJob is called 
+  after RunAfterJob, and NewVolume, is called before all other 
+  "methods" of obtaining a new Volume name, when one is needed.
+
+  The Python script of the same name as the Event name (but with a .py) 
+  is called from the Scripts Directory (a directive defined in the
+  Director resource).  Note, both the Filename, and the name of
+  the function in the file must correspond to the Event name.
+
+  Once the Python script gets control, it can have access to Bacula
+  variables by doing:
+
+     import bacula
+
+  The script is called with one argument, typically called j. This
+  argument *must* be passed unchanged to each bacula function. The
+  format of the call is slightly different for reading Bacula
+  variable and for writing bacula variables. See below.
+
+  Bacula variables can be read with:
+
+     bacula.get(j, "Variable-name")
+
+    where j is the argument passed to the function, and Variable-name
+    is on of the following:
+
+     JobId, Client, Pool, Storage, Catalog, MediaType, NumVols, DirName,
+       Level, Type, Job, JobName, JobStatus
+
+   Bacula varibles can be set using Python keyword arguments:
+
+      bacula.set(jcr=j, VolumeName="xyz")
+
+    The two currently implemented writable "variables" are:
+
+    VolumeName and JobReport
+
+   It is possible to submit a Bacula run command with the following:
+
+     bacula.run(j, "run kernsave client=Matou storage=File")
+
+   this function returns the JobId of the job that was started. If
+   there is an error, the return value is zero.
+
+   Example:
+
+== File EndJob.py ===
+import bacula
+
+def EndJob(j):
+    jobid = bacula.get(j, "JobId")
+    client = bacula.get(j, "Client") 
+    bacula.set(jcr=j, JobReport="EndJob output: JobId=%d Client=%s.\n" % (jobid, client))
+    if (jobid < 5) :
+       startid = bacula.run(j, "run kernsave")
+       print "Python started jobid=", startid
+
+    return 1
+====
+
+== File NewVolume.py ===
+import bacula
+
+def NewVolume(j):
+    jobid = bacula.get(j, "JobId")
+    print "JobId=", jobid
+    client = bacula.get(j, "Client") 
+    print "Client=" + client
+    numvol = bacula.get(j, "NumVols");
+    print "NumVols=", numvol
+    bacula.set(jcr=j, JobReport="New Volume set for Job.\n") 
+    bacula.set(jcr=j, VolumeName="TestA-001")
+    return 1
+====