 \index[general]{Labels!Tape}
 \addcontentsline{toc}{section}{ANSI and IBM Tape Labels}
 
-Bacula can support ANSI or IBM tape labels as long as you
+Bacula supports ANSI or IBM tape labels as long as you
 enable it.  In fact, with the proper configuration, you can
 force Bacula to require ANSI or IBM labels.
 
@@ -18,18 +18,27 @@ will recognize and support them.
 Even though Bacula will recognize and write ANSI and IBM labels, 
 it always writes its own tape labels as well.
 
-When using ANSI or IBM tape labeling, you must keep your Volume
+When using ANSI or IBM tape labeling, you must restrict your Volume
 names to a maximum of 6 characters.  
 
+If you have labeled your Volumes outside of Bacula, then the
+ANSI/IBM label will be recognized by Bacula only if you have created
+the HDR1 label with {\bf BACULA.DATA} in the Filename field (starting
+with character 5).  If Bacula writes the labels, it will use
+this information to recognize the tape as a Bacula tape.  This allows
+ANSI/IBM labeled tapes to be used at sites with multiple machines
+and multiple backup programs.
+
 
 \subsection*{Director Pool Directive}
 \addcontentsline{toc}{section}{Director Pool Directive}
 
 \begin{description}
 \item [ Label Type = ANSI | IBM | Bacula]  
-  This directive is implemented in Director Pool resource and in SD Device
+  This directive is implemented in the Director Pool resource and in the SD Device
   resource.  If it is specified in the SD Device resource, it will take
-  precedence over the value passed from the Director to the SD.
+  precedence over the value passed from the Director to the SD. The default
+  is Label Type = Bacula.
 \end{description}
 
 \subsection*{Storage Daemon Device Directives}
@@ -37,14 +46,17 @@ names to a maximum of 6 characters.
 
 \begin{description}
 \item [ Label Type = ANSI | IBM | Bacula]  
-  This directive is implemented in Director Pool resource and in SD Device
-  resource.  If it is specified in the SD Device resource, it will take
+  This directive is implemented in the Director Pool resource and in the SD Device
+  resource.  If it is specified in the the SD Device resource, it will take
   precedence over the value passed from the Director to the SD.
-
 \item [Check Labels = yes | no]
-  This directive is implemented in the SD Device resource.  If you intend
+  This directive is implemented in the the SD Device resource.  If you intend
   to read ANSI or IBM labels, this *must* be set.  Even if the volume is
   not ANSI labeled, you can set this to yes, and Bacula will check the
-  label type.
+  label type. Without this directive set to yes, Bacula will assume that
+  labels are of Bacula type and will not check for ANSI or IBM labels.
+  In other words, if there is a possibility of Bacula encountering an
+  ANSI/IBM label, you must set this to yes.
 \end{description}