For the {\bf purge} command to work on Volume Catalog database records the
{\bf VolStatus} must be Append, Full, Used, or Error.
-The actual data written to the Volume will be unaffected by this command.
+The actual data written to the Volume will be unaffected by this command unless
+you are using the \texttt{ActionOnPurge=Truncate} option on those Media.
+
+To ask Bacula to truncate your \texttt{Purged} volumes, you need to use the
+following command in interactive mode or in a RunScript:
+\begin{verbatim}
+*purge volume action=truncate storage=File allpools
+# or by default, action=all
+*purge volume action storage=File pool=Default
+\end{verbatim}
+
+This is possible to specify the volume name, the media type, the pool, the
+storage, etc\dots (see \texttt{help purge}) Be sure that your storage device is
+idle when you decide to run this command.
\item[python]
\index[general]{python}