]> git.sur5r.net Git - bacula/docs/blobdiff - docs/manuals/en/install/dirdconf.tex
Merge branch 'master' of ssh://ricozz@bacula.git.sourceforge.net/gitroot/bacula/docs
[bacula/docs] / docs / manuals / en / install / dirdconf.tex
index 93b21050840023720ebccdcd1d931d7197502d72..c19f0793854c729cec96c3bfedba69b0b207f124 100644 (file)
@@ -419,7 +419,7 @@ the FileSets may be the same).
    specify here followed by the date and time the  job was scheduled for
    execution. This directive is required. 
 
-\item [Enabled = \lt{}yes|no\gt{}]
+\item [Enabled = \lt{}yes\vb{}no\gt{}]
   \index[dir]{Enable}
   \index[dir]{Directive!Enable}
   This directive allows you to enable or disable automatic execution
@@ -510,7 +510,7 @@ For a {\bf Backup} Job, the Level may be one of the  following:
    different FileSet.  
 \item The Job was a Full, Differential, or Incremental backup.  
 \item The Job terminated normally (i.e. did not fail or was not  canceled).  
-\item The Job started no longer ago than {\bf Max Full Age}.
+\item The Job started no longer ago than {\bf Max Full Interval}.
 \end{itemize}
 
    If all the above conditions do not hold, the Director will upgrade  the
@@ -573,7 +573,7 @@ For a {\bf Backup} Job, the Level may be one of the  following:
    different FileSet.  
 \item The Job was a FULL backup.  
 \item The Job terminated normally (i.e. did not fail or was not  canceled).  
-\item The Job started no longer ago than {\bf Max Full Age}.
+\item The Job started no longer ago than {\bf Max Full Interval}.
 \end{itemize}
 
    If all the above conditions do not hold, the Director will  upgrade the
@@ -712,7 +712,7 @@ For a {\bf Verify} Job, the Level may be one of the  following:
    have been deleted.
 \end{description}
 
-\item [Accurate = \lt{}yes|no\gt{}]
+\item [Accurate = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Accurate}
    In accurate mode, the File daemon knowns exactly which files were present
    after the last backup. So it is able to handle deleted or renamed files.
@@ -969,9 +969,9 @@ during working hours. We can see it like \texttt{Max Start Delay + Max Run
 \addcontentsline{lof}{figure}{Job time control directives}
 \includegraphics{\idir different_time.eps}
 
-\item [Max Full Age = \lt{}time\gt{}]
-\index[dir]{Max Full Age}
-\index[dir]{Directive!Max Full Age}
+\item [Max Full Interval = \lt{}time\gt{}]
+\index[dir]{Max Full Interval}
+\index[dir]{Directive!Max Full Interval}
    The time specifies the maximum allowed age (counting from start time) of
    the most recent successful Full backup that is required in order to run
    Incremental or Differential backup jobs. If the most recent Full backup
@@ -981,7 +981,7 @@ during working hours. We can see it like \texttt{Max Start Delay + Max Run
    considered.
 
 \label{PreferMountedVolumes}
-\item [Prefer Mounted Volumes = \lt{}yes|no\gt{}]
+\item [Prefer Mounted Volumes = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Prefer Mounted Volumes}
 \index[dir]{Directive!Prefer Mounted Volumes}
    If the Prefer Mounted Volumes directive is set to {\bf yes} (default
@@ -1017,7 +1017,7 @@ during working hours. We can see it like \texttt{Max Start Delay + Max Run
    pools so that Bacula will be forced to mount Volumes from those Pools
    on different drives.
 
-\item [Prune Jobs = \lt{}yes|no\gt{}]
+\item [Prune Jobs = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Prune Jobs}
 \index[dir]{Directive!Prune Jobs}
    Normally, pruning of Jobs from the Catalog is specified on a Client by
@@ -1027,7 +1027,7 @@ during working hours. We can see it like \texttt{Max Start Delay + Max Run
    default is {\bf no}.
 
 
-\item [Prune Files = \lt{}yes|no\gt{}]
+\item [Prune Files = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Prune Files}
 \index[dir]{Directive!Prune Files}
    Normally, pruning of Files from the Catalog is specified on a Client by
@@ -1036,7 +1036,7 @@ during working hours. We can see it like \texttt{Max Start Delay + Max Run
    yes}, it will override the value specified in the Client resource.  The
    default is {\bf no}.
 
-\item [Prune Volumes = \lt{}yes|no\gt{}]
+\item [Prune Volumes = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Prune Volumes}
 \index[dir]{Directive!Prune Volumes}
    Normally, pruning of Volumes from the Catalog is specified on a Client
@@ -1457,7 +1457,7 @@ RunScript {
    Note, please see the notes above in {\bf RunScript} 
    concerning Windows clients.
 
-\item [Rerun Failed Levels = \lt{}yes|no\gt{}]
+\item [Rerun Failed Levels = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Rerun Failed Levels}
    \index[dir]{Directive!Rerun Failed Levels}
    If this directive is set to {\bf yes} (default no), and Bacula detects that
@@ -1475,7 +1475,7 @@ RunScript {
    when checking for failed levels, which means that any FileSet change will
    trigger a rerun.
 
-\item [Spool Data = \lt{}yes|no\gt{}]
+\item [Spool Data = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Spool Data}
    \index[dir]{Directive!Spool Data}
 
@@ -1490,7 +1490,7 @@ RunScript {
    NOTE: When this directive is set to yes, Spool Attributes is also
    automatically set to yes.
 
-\item [Spool Attributes = \lt{}yes|no\gt{}]
+\item [Spool Attributes = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Spool Attributes}
    \index[dir]{Directive!Spool Attributes}
    \index[dir]{slow}
@@ -1597,7 +1597,7 @@ RunScript {
   if the backed up file already exists, Bacula skips  restoring this file.  
 \end{description}
 
-\item [Prefix Links=\lt{}yes|no\gt{}]
+\item [Prefix Links=\lt{}yes\vb{}no\gt{}]
    \index[dir]{Prefix Links}
    \index[dir]{Directive!Prefix Links}
    If a {\bf Where} path prefix is specified for a recovery job, apply it
@@ -1621,7 +1621,7 @@ RunScript {
    documented under \ilink{ Maximum Concurrent Jobs}{DirMaxConJobs} in the
    Director's resource.
 
-\item [Reschedule On Error = \lt{}yes|no\gt{}]
+\item [Reschedule On Error = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Reschedule On Error}
    \index[dir]{Directive!Reschedule On Error}
    If this directive is enabled, and the job terminates in error, the job
@@ -1746,7 +1746,7 @@ priority ones.  This insures that Bacula will examine the jobs in the
 correct order, and that your priority scheme will be respected.
 
 \label{AllowMixedPriority}
-\item [Allow Mixed Priority = \lt{}yes|no\gt{}]
+\item [Allow Mixed Priority = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Allow Mixed Priority}
    This directive is only implemented in version 2.5 and later.  When
    set to {\bf yes} (default {\bf no}), this job may run even if lower
@@ -1763,7 +1763,7 @@ correct order, and that your priority scheme will be respected.
    be run until the priority 5 job has finished.
 
 \label{WritePartAfterJob}
-\item [Write Part After Job = \lt{}yes|no\gt{}]
+\item [Write Part After Job = \lt{}yes\vb{}no\gt{}]
 \index[dir]{Write Part After Job}
 \index[dir]{Directive!Write Part After Job}
    This directive is only implemented in version 1.37 and later.
@@ -1913,7 +1913,7 @@ upgraded from another type  to a full backup.
    specifies to use the Pool  named {\bf Incremental} if the job is an
 incremental  backup.  
 
-\item [SpoolData=yes|no]
+\item [SpoolData=yes\vb{}no]
    \index[dir]{SpoolData}
    \index[dir]{Directive!SpoolData}
    tells Bacula to request the Storage  daemon to spool data to a disk file
@@ -1931,7 +1931,7 @@ incremental  backup.
    This directive is available only in Bacula version 2.3.5 or 
    later.
 
-\item [WritePartAfterJob=yes|no]
+\item [WritePartAfterJob=yes\vb{}no]
    \index[dir]{WritePartAfterJob}
    \index[dir]{Directive!WritePartAfterJob}
    tells Bacula to request the Storage daemon to write the current part
@@ -2226,7 +2226,7 @@ console run command.  This directive is required.
    The default is 180 days.  
 
 \label{AutoPrune}
-\item [AutoPrune = \lt{}yes|no\gt{}]
+\item [AutoPrune = \lt{}yes\vb{}no\gt{}]
    \index[dir]{AutoPrune}
    \index[dir]{Directive!AutoPrune}
    If AutoPrune is set to  {\bf yes} (default), Bacula (version 1.20 or greater)
@@ -2401,7 +2401,7 @@ the Director.
    check so that you don't try to write data for a DLT onto an 8mm device.
 
 \label{Autochanger1}
-\item [Autochanger = \lt{}yes|no\gt{}]  
+\item [Autochanger = \lt{}yes\vb{}no\gt{}]  
    \index[dir]{Autochanger}
    \index[dir]{Directive!Autochanger}
    If you specify {\bf yes} for this command (the default is {\bf no}),
@@ -2599,7 +2599,7 @@ The Pool Resource defined in the Director's configuration file
    the Job resource or in the Pool, but it must be specified in
    one or the other.  If not configuration error will result.
 
-\item [Use Volume Once = \lt{}yes|no\gt{}]
+\item [Use Volume Once = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Use Volume Once}
    \index[dir]{Directive!Use Volume Once}
    This directive if set to {\bf yes} specifies that each volume is to be
@@ -2729,7 +2729,7 @@ The Pool Resource defined in the Director's configuration file
    must use the 
    \ilink{\bf update volume}{UpdateCommand} command in the Console.  
 
-\item [Catalog Files = \lt{}yes|no\gt{}]
+\item [Catalog Files = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Catalog Files}
    \index[dir]{Directive!Catalog Files}
    This directive defines whether or not you want the names of the files
@@ -2742,7 +2742,7 @@ The Pool Resource defined in the Director's configuration file
    restore} command nor any other command that references File entries.
    
 \label{PoolAutoPrune}
-\item [AutoPrune = \lt{}yes|no\gt{}]
+\item [AutoPrune = \lt{}yes\vb{}no\gt{}]
    \index[dir]{AutoPrune}
    \index[dir]{Directive!AutoPrune}
    If AutoPrune is set to {\bf yes} (default), Bacula (version 1.20 or
@@ -2832,7 +2832,7 @@ The Pool Resource defined in the Director's configuration file
         
    
 \label{PoolRecycle}
-\item [Recycle = \lt{}yes|no\gt{}]
+\item [Recycle = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Recycle}
    \index[dir]{Directive!Recycle}
    This directive specifies whether or not Purged Volumes may be recycled.
@@ -2861,7 +2861,7 @@ The Pool Resource defined in the Director's configuration file
 
 
 \label{RecycleOldest}
-\item [Recycle Oldest Volume = \lt{}yes|no\gt{}]
+\item [Recycle Oldest Volume = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Recycle Oldest Volume}
    \index[dir]{Directive!Recycle Oldest Volume}
    This directive instructs the Director to search for the oldest used
@@ -2885,7 +2885,7 @@ The Pool Resource defined in the Director's configuration file
 
 \label{RecycleCurrent}
 
-\item [Recycle Current Volume = \lt{}yes|no\gt{}]
+\item [Recycle Current Volume = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Recycle Current Volume}
    \index[dir]{Directive!Recycle Current Volume}
    If Bacula needs a new Volume, this directive instructs Bacula to Prune
@@ -2908,7 +2908,7 @@ The Pool Resource defined in the Director's configuration file
 
 \label{PurgeOldest}
 
-\item [Purge Oldest Volume = \lt{}yes|no\gt{}]
+\item [Purge Oldest Volume = \lt{}yes\vb{}no\gt{}]
    \index[dir]{Purge Oldest Volume}
    \index[dir]{Directive!Purge Oldest Volume}
    This directive instructs the Director to search for the oldest used
@@ -3108,7 +3108,7 @@ defined.
    by MySQL and PostgreSQL and is ignored by SQLite if provided.  This
    directive is optional.
 
-%% \item [Multiple Connections = \lt{}yes|no\gt{}]
+%% \item [Multiple Connections = \lt{}yes\vb{}no\gt{}]
 %% \index[dir]{Multiple Connections}
 %% \index[dir]{Directive!Multiple Connections}
 %% By default, this  directive is set to no. In that case, each job that uses