two jobs in the same restore if the Jobs' data blocks were
intermixed on the backup medium. The problem is resolved by
simply doing two restores, one for each Job.
+ Normally this can happen only if you manually enter specific
+ JobIds to be restored in a single restore Job.
\item Bacula can generally restore any backup made from one client
to any other client. However, if the architecture is significantly
different (i.e. 32 bit architecture to 64 bit or Win32 to Unix),
this does not apply to filenames, which may be arbitrarily long.
\item Command line input to some of the stand alone tools -- e.g. btape,
bconsole is restricted to several hundred characters maximum.
+ Normally, this is not a restriction, except in the case of listing
+ multiple Volume names for programs such as {\bf bscan}. To avoid
+ this command line length restriction, please use a {\bf .bsr}
+ file to specify the Volume names.
+\item Bacula configuration files for each of the components can be
+ any length. However, the length of an individual line is limited
+ to 500 characters after which it is truncated. If you need lines
+ longer than 500 characters for directives such as ACLs where
+ they permit a list of names are character strings simply
+ specify multiple short lines repeating the directive on
+ each line but with different list values.
+
\end{itemize}
\section{Items to Note}