# This script uses the autochanger and two tapes
#
-debug=1
-if test "$debug" -eq 1 ; then
- out="tee"
-else
- out="output"
+. config.out
+if test x${TAPE_DRIVE1} = x/dev/null ; then
+ echo "Skipping 2drive-incremenatal-2tape test. No second drive."
+ exit
fi
+TestName="2drive-incremental-2tape"
+JobName="2drive2tape"
+. scripts/functions
+set_debug 0
+
cwd=`pwd`
-bin/bacula stop 2>&1 >/dev/null
-cd bin
-./drop_bacula_tables >/dev/null 2>&1
-./make_bacula_tables >/dev/null 2>&1
-./grant_bacula_privileges 2>&1 >/dev/null
-cd ..
scripts/copy-2drive-confs
scripts/cleanup-2drive
+
+change_jobname localhost-fd $JobName
+
echo "${cwd}/tmp/build" >/tmp/file-list
if test ! -d ${cwd}/tmp/build ; then
mkdir ${cwd}/tmp/build
echo "${cwd}/tmp/build/ficheriro2.txt" >>restore-list
cd ${cwd}
-echo " "
-echo " "
-echo " === Starting 2drive-incremental-2tape test ==="
-echo " === Starting 2drive-incremental-2tape test ===" >>working/log
-echo " "
+# Turn off Prefer Mounted Volumes so we use 2 drives
+outf="tmp/sed_tmp"
+echo "s%# Prefer Mounted Volumes% Prefer Mounted Volumes%g" >${outf}
+cp ${cwd}/bin/bacula-dir.conf ${cwd}/tmp/1
+# Comment the next line out to write everything to one drive
+# otherwise, it writes the two jobs to different drives
+sed -f ${outf} ${cwd}/tmp/1 >${cwd}/bin/bacula-dir.conf
+
+start_test
# Write out bconsole commands
cat <<END_OF_DATA >tmp/bconcmds
-@$out /dev/null
+@output /dev/null
messages
@$out tmp/log1.out
-label storage=DDS-4 volume=TestVolume001 slot=1 Pool=Default
-label storage=DDS-4 volume=TestVolume002 slot=2 Pool=Default
+label storage=DDS-4 volume=TestVolume001 slot=1 Pool=Default drive=0
+label storage=DDS-4 volume=TestVolume002 slot=2 Pool=Default drive=1
+@#setdebug level=100 storage=DDS-4
+run job=NightlySave yes
+run job=NightlySave yes
+run job=NightlySave yes
+run job=NightlySave yes
run job=NightlySave yes
+@sleep 3
+status storage=DDS-4
wait
+list volumes
+list jobs
+status storage=DDS-4
messages
quit
END_OF_DATA
-if test "$debug" -eq 1 ; then
- bin/bacula start
- cat tmp/bconcmds | bin/bconsole -c bin/bconsole.conf
-else
- bin/bacula start 2>&1 >/dev/null
- cat tmp/bconcmds | bin/bconsole -c bin/bconsole.conf 2>&1 >/dev/null
-fi
+run_bacula
+
echo "ficheriro1.txt" >${cwd}/tmp/build/ficheriro1.txt
echo "ficheriro2.txt" >${cwd}/tmp/build/ficheriro2.txt
-bin/bconsole -c bin/bconsole.conf <<END_OF_DATA
+
+cat <<END_OF_DATA >tmp/bconcmds
@$out /dev/null
messages
@$out tmp/log1.out
@# Force Incremental on the second Volume
update volume=TestVolume001 VolStatus=Used
+status storage=DDS-4
+@#setdebug level=400 storage=DDS-4
run level=Incremental job=NightlySave yes
wait
+list volumes
+status storage=DDS-4
messages
@#
@# now do a restore
@$out
quit
END_OF_DATA
-bin/bacula stop 2>&1 >/dev/null
-grep "^ Termination: *Backup OK" tmp/log1.out 2>&1 >/dev/null
-bstat=$?
-grep "^ Termination: *Restore OK" tmp/log2.out 2>&1 >/dev/null
-rstat=$?
+
+run_bconsole
+check_for_zombie_jobs storage=DDS-4
+stop_bacula
+
+check_two_logs
#
# Delete .c files because we will only restored the txt files
#
rm -f tmp/build/*.c
-diff -r tmp/build tmp/bacula-restores${cwd}/tmp/build 2>&1 >/dev/null
-if [ $? != 0 -o $bstat != 0 -o $rstat != 0 ] ; then
- echo " "
- echo " "
- echo " !!!!! 2drive-incremental-2tape test Bacula source failed!!! !!!!! "
- echo " !!!!! 2drive-incremental-2tape test failed!!! !!!!! " >>test.out
- echo " "
-else
- echo " ===== 2drive-incremental-2tape test Bacula source OK ===== "
- echo " ===== 2drive-incremental-2tape test OK ===== " >>test.out
- scripts/cleanup
-fi
+check_restore_tmp_build_diff
+
+end_test