# Note we use the viritual disk autochanger
#
+TestName="two-volume-test"
+JobName=TwoVolume
+. scripts/functions
+set_debug 1
. config.out
-if test x${AUTOCHANGER} = x/dev/null ; then
- echo "two-volume-test skipped. No autochanger."
- exit
-fi
-debug=0
-if test "$debug" -eq 1 ; then
- out="tee"
-else
- out="output"
-fi
+
cwd=`pwd`
scripts/cleanup
scripts/copy-2disk-confs
cp ${cwd}/bin/bacula-sd.conf ${cwd}/tmp/1
sed -f ${outf} ${cwd}/tmp/1 >${cwd}/bin/bacula-sd.conf
-echo " "
-echo " "
-echo " === Starting Two Volume Test at `date +%R:%S` ==="
-echo " === Starting Two Volume Test at `date +%R:%S` ===" >>working/log
-echo " "
+change_jobname NightlySave $JobName
+start_test
+
# Write out bconsole commands
cat <<END_OF_DATA >tmp/bconcmds
@$out /dev/null
label storage=DDS-4 volume=TestVolume002 slot=2 pool=Default drive=0
update Volume=TestVolume001 MaxVolBytes=3000000 pool=Default drive=0
@#setdebug level=1000 client
-run job=NightlySave yes
+run job=$JobName yes
wait
messages
@#
quit
END_OF_DATA
-if test "$debug" -eq 1 ; then
- bin/bacula start
- cat tmp/bconcmds | bin/bconsole -c bin/bconsole.conf
-else
- bin/bacula start 2>&1 >/dev/null
- cat tmp/bconcmds | bin/bconsole -c bin/bconsole.conf 2>&1 >/dev/null
-fi
-scripts/check_for_zombie_jobs storage=DDS-4
+run_bacula
+check_for_zombie_jobs storage=DDS-4
+stop_bacula
-bin/bacula stop 2>&1 >/dev/null
-grep "^ Termination: *Backup OK" tmp/log1.out 2>&1 >/dev/null
-bstat=$?
-grep "^ Termination: *Restore OK" tmp/log2.out 2>&1 >/dev/null
-rstat=$?
-diff -r build tmp/bacula-restores${cwd}/build 2>&1 >/dev/null
-if [ $? != 0 -o $bstat != 0 -o $rstat != 0 ] ; then
- echo " "
- echo " "
- echo " !!!!! Two Volume Test Bacula source failed!!! !!!!! "
- echo " !!!!! Two Volume Test failed!!! !!!!! " >>test.out
- echo " "
-else
- echo " ===== Two Volume Test Bacula source OK `date +%R:%S` ===== "
- echo " ===== Two Volume Test OK `date +%R:%S` ===== " >>test.out
- scripts/cleanup
-fi
+check_two_logs
+check_restore_diff
+end_test